    Doses Received by Patients during Thorax X-Ray Examinations

    (ندگان)پدیدآور
    U. Esen, NsikanObed, Rachel. I.
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    168.4کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction Radiation exposures from diagnostic medical examinations are generally low and are almost always justified by the benefits of accurate diagnosis of possible disease conditions. Therefore, entrance skin dose (ESD), body organ dose (BOD), and effective dose (ED) from adult patients undergoing routine thorax posterior-anterior (PA) and thorax right lateral (RLAT) were estimated in University Hospital, Port Harcourt, Southern Nigeria. Materials and Methods Totally, 102 patients were considered in this work. Using software packages to carry out ESD, BOD, and ED is a recent resource in dosimetry and is being widely used in hospitals. The software used in this work was  CALDose_X 5.0. The software makes use of the technical exposure parameters and the tube output of the X-ray machine. Results The estimated ESD median values were 0.96 and 1.85 mGy for thorax posterior anterior (PA) and right lateral (RLAT), respectively. The highest BOD was in the adrenals (270 µGy) for thorax PA and Liver (263 µGy) for thorax RLAT. Similarly, ED for thorax PA and RLAT examination were 0.068 and 0.107 mGy, respectively. Conclusion It could be observed that examinations that imparted the highest ESD were thorax PA when compared with the established dose level. Therefore, these results call for quality assurance program (QAP) in diagnostic X-ray units in Nigeria hospitals.
    کلید واژگان
    Entrance Skin Dose
    Effective Dose
    Radiography
    Medical Physics
    Physics of Diagnostics Radiology
    Radiation Detection & Measurement

    شماره نشریه
    4
    تاریخ نشر
    2012-12-01
    1391-09-11
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    - Department of Physics, Akwa Ibom State University, PMB 1167 Uyo, Nigeria
    Department of Physics, University of Ibadan, Ibadan, Nigeria

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2013.467
    http://ijmp.mums.ac.ir/article_467.html
    https://iranjournals.nlai.ir/handle/123456789/324951

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب