    Size Effects of Gold and Iron Nanoparticles on Radiation Dose Enhancement in Brachytherapy and Teletherapy: A Monte Carlo Study

    (ندگان)پدیدآور
    Ezzati, Ahad OllahMahdavi, Seyed RabiAnijdan, Hossein Mousavie
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    273.5کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction In this study, we aimed to calculate dose enhancement factor (DEF) for gold (Au) and iron (Fe) nanoparticles (NPs) in brachytherapy and teletherapy, using Monte Carlo (MC) method. Materials and Methods In this study, a new algorithm was introduced to calculate dose enhancement by AuNPs and FeNPs for Iridium-192 (Ir-192) brachytherapy and Cobalt-60 (Co-60) teletherapy sources, using the MC method. In this algorithm, the semi-random distribution of NPs was used instead of the regular distribution. Diameters were assumed to be 15, 30, and 100 nm in brachytherapy and 15 and 30 nm in teletherapy. Monte Carlo MCNP4C code was used for simulations, and NP density values were 0.107 mg/ml and 0.112 mg/ml in brachytherapy and teletherapy, respectively. Results AuNPs significantly enhanced the radiation dose in brachytherapy (approximately 60%), and 100 nm diameter NPs showed the most uniform dose distribution. AuNPs had an insignificant effect on teletherapy radiation field, with a dose enhancement ratio of 3% (about the calculation uncertainty) or less. In addition, FeNPs had an insignificant effect on both brachytherapy and teletherapy radiation fields. FeNPs dose enhancement was 3% in brachytherapy and 6% (about the calculation uncertainty) or less in teletherapy. Conclusion It can be concluded that AuNPs can significantly increase the absorbed dose in brachytherapy; however, FeNPs do not have a noticeable effect on the absorbed dose
    کلید واژگان
    Brachytherapy
    Dose Enhancement Factor
    Monte Carlo
    Nanoparticle
    Medical Application of Computer Simulation
    Medical Physics
    Nanomedicine
    Physics of Radiotherapy

    شماره نشریه
    23
    تاریخ نشر
    2014-08-01
    1393-05-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Faculty of Physics, University of Tabriz, Tabriz, Iran
    Department of Medical Physics, Iran University of Medical Sciences, Tehran, Iran
    Department of Medical Physics, Babol University of Medical Sciences, Babol, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2014.3098
    http://ijmp.mums.ac.ir/article_3098.html
    https://iranjournals.nlai.ir/handle/123456789/324943

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب