    Calculation of Inter- and Intra-Fraction Motion Errors at External Radiotherapy Using a Markerless Strategy Based on Image Registration Combined with Correlation Model

    (ندگان)پدیدآور
    Samadi Miandoab, PayamEsmaili Torshabi, Ahmadparandeh, Sohelia
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.056 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: A new method based on image registration technique and an intelligent correlation model to calculate. The present study aimed to propose inter- and intra-fraction motion errors in order to address the limitations of conventional Patient positioning methods. Material and Methods: The configuration of the markerless method was accomplished by using four-dimensional computed tomography (4DCT) datasets. Firstly, the MeVisLab software package was used to extract a three-dimensional (3D) surface model of the patient and determine the tumor location. Then, the patient-specific 3D surface model which also included the breathing phases was imported into the MATLAB software package in order to define several control points on the thorax region as virtual external markers. Finally, based on the correlation of breathing signals/patient position with breathing signals/tumor coordinate, an adaptive neuro fuzzy inference system was proposed to both verify and align the inter- and intra-fraction motion errors in radiotherapy, if needed. In order to validate the proposed method, the 4DCT data acquired from four real patients was considered. Results: Final results revealed that our hybrid configuration method was capable of aligning patient setup with lower uncertainties, compared to other available methods. In addition, the 3D root-mean-square error has been reduced from 5.26 to 1.5 mm for all patients. Conclusion: In this study, a markerless method based on the image registration technique in combination with a correlation model was proposed to address the limitations of the available methods, including dependence on operator's attention, use of passive markers, and rigid-only constraint for patient setup.
    کلید واژگان
    Image Processing
    Image Guided Radiation Therapy (IGRT)
    patient positioning
    Medical Application of Computer Simulation
    Medical Physics
    Physics of Radiotherapy

    شماره نشریه
    3
    تاریخ نشر
    2019-05-01
    1398-02-11
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Department of Electrical and Computer Engineering, Medical Radiation Group, Graduate University of Advanced Technology, Haft Bagh Highway, Knowledge Paradise, Kerman, Iran.
    Medical Radiation Division, Dept. of Electrical and Computer Eng. Graduate University of Advanced Technology, Kerman, Iran
    Department of Electrical and Computer Engineering, Medical Radiation Group, Graduate University of Advanced Technology, Haft Bagh Highway, Knowledge Paradise, Kerman, Iran.

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2018.30477.1348
    http://ijmp.mums.ac.ir/article_11054.html
    https://iranjournals.nlai.ir/handle/123456789/324904

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب