    Calculation of the X-Ray Spectrum of a Mammography System with Various Voltages and Different Anode-Filter Combinations Using MCNP Code

    (ندگان)پدیدآور
    Gholamkar, LidaSadeghi, MahdiMowlavi, Ali AsgharAthari, Mitra
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    782.2کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction One of the best methods in the diagnosis and control of breast cancer is mammography. The importance of mammography is directly related to its value in the detection of breast cancer in the early stages, which leads to a more effective treatment. The purpose of this article was to calculate the X-ray spectrum in a mammography system with Monte Carlo codes, including MCNPX and MCNP5. Materials and Methods The device, simulated using the MCNP code, was Planmed Nuance digital mammography device (Planmed Oy, Finland), equipped with an amorphous selenium detector. Different anode/filter materials, such as molybdenum-rhodium (Mo-Rh), molybdenum-molybdenum (Mo-Mo), tungsten-tin (W-Sn), tungsten-silver (W-Ag), tungsten-palladium (W-Pd), tungsten-aluminum (W-Al), tungsten-molybdenum (W-Mo), molybdenum-aluminum (Mo-Al), tungsten-rhodium (W-Rh), rhodium-aluminum (Rh-Al), and rhodium-rhodium (Rh-Rh), were simulated in this study. The voltage range of the X-ray tube was between 24 and 34 kV with a 2 kV interval. Results The charts of changing photon flux versus energy were plotted for different types of anode-filter combinations. The comparison with the findings reported by others indicated acceptable consistency. Also, the X-ray spectra, obtained from MCNP5 and MCNPX codes for W-Ag and W-Rh combinations, were compared. We compared the present results with the reported data of MCNP4C and IPEM report No. 78 for Mo-Mo, Mo-Rh, and W-Al combinations. Conclusion The MCNPX calculation outcomes showed acceptable results in a low-energy X-ray beam range (10-35 keV). The obtained simulated spectra for different anode/filter combinations were in good conformity with the finding of previous research.
    کلید واژگان
    Anodes
    Filters
    Full-field digital mammography system
    MCNP code
    Monte Carlo Method
    X-ray spectrum
    Medical Application of Computer Simulation
    Medical Physics
    Physics of Diagnostics Radiology

    شماره نشریه
    3
    تاریخ نشر
    2016-09-01
    1395-06-11
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Department of Medical Radiation Engineering, Science and Research branch, Islamic Azad University, Tehran, Iran,
    Medical Physics Department, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
    Physics Department, School of Sciences, Hakim Sabzevari University, Sabzevar, Iran. ICTP, Associate federation Scheme, Medical Physics Field, Trieste, Italy.
    Department of Medical Radiation Engineering, Science and Research branch, Islamic Azad University, Tehran, Iran,

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2016.7959
    http://ijmp.mums.ac.ir/article_7959.html
    https://iranjournals.nlai.ir/handle/123456789/324866

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب