    Assessment of Patient Radiation Dose in Interventional Procedures at Shahid Madani Heart Center in Khorramabad, Iran

    (ندگان)پدیدآور
    Gholami, Mehrdadgharloghi, SomayehZare, SoodabehSaki, ArezooPiri, ZahraMousavi, Majid
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.084 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Coronary angiography is the most common angiographic procedure for diagnosis and treatment of the heart diseases. Herein, we aimed to evaluate the entrance surface dose (ESD), dose area product (DAP), as well as cancer risk in interventional cardiology procedures. Materials and Methods: This study was conducted during July-December 2015 at Shahid Madani Heart Center in Khorramabad, Iran. A total of 225 adult patients including 122 females and 103 males regardless of the risk factors for coronary diseases were participated. Of them, 199 and 26 patients underwent diagnostic coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA), respectively. Each patient underwent CA or PTCA separately. All the procedures were carried out using Siemens angiography system with the pulsed fluoroscopy of 10-30 pulses/s and cine frame rate of 15 frames/s. DAP, ESD, fluoroscopy time (FT), as well as the number of sequences and frames per sequence were collected for each 199 CA and 26 PTCA procedures. Results: The median values of DAP were 19.77±14.88 and 57.11±33.36 Gy.cm2 in CA and PTCA, respectively. In addition, the median values of ESD were 323.12±245.39 and 1145.22±594.42 mGy in CA and PTCA, respectively. FTs were 114.59±74.33 s in CA and 424.15±292.93 s in PTCA. Conclusion: The average patient dose and cancer risk estimates in both CA and PTCA were consistent with the reference levels. However, in agreement with other interventional procedures, dose levels in the interventional cardiology are influenced by staff and clinical protocols, as well as the type of equipment.
    کلید واژگان
    Coronary Angiography Entrance Surface Dose
    Dose Area Product
    Effective Dose
    Radiation risk
    Medical Physics
    Physics of Diagnostics Radiology
    Radiation Detection & Measurement

    شماره نشریه
    3
    تاریخ نشر
    2017-09-01
    1396-06-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Department of Medical Physics & Radiation Sciences, Lorestan University of Medical Sciences, Khorram Abad, Iran
    Department of Medical physics and Radiation Sciences, School of Para Medicine, Lorestan University of Medical Sciences, Khorramabad, Iran
    Department of Public Health, Lorestan University of Medical Sciences, Khorramabad, Iran
    Student Research Committee, Lorestan University of Medical Sciences, Khorramabad, Iran
    Student Research Committee, Lorestan University of Medical Sciences, Khorramabad, Iran
    Angiography and Angioplasty section, Shahid Madani Heart Center, Lorestan University of Medical Sciences, Khorramabad, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2017.22500.1212
    http://ijmp.mums.ac.ir/article_8836.html
    https://iranjournals.nlai.ir/handle/123456789/324828

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب