    Organ Dose Measurement in Computed Tomography Using Thermoluminescence Dosimeter in Locally Developed Phantoms

    (ندگان)پدیدآور
    Akpochafor, MichaelADENEYE, SAMUELHabeebu, MuhammadOMOJOLA, AKINTAYOAdedewe, NusiratAdedokun, AderonkeAdewa, DareAJIBADE, SUNDAYEkpo, VictorAweda, Moses
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1006.کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Organ dose estimation using thermoluminescence dosimeter (TLD) is known to be a standard, although many other methods, such as simulation software, optically stimulated luminescent dosimeters, and photodiodes are still in use. This study aimed at directly measuring mean organ doses to the selected organs in the head/neck, chest, and abdominal regions from four computed tomography (CT) units in Lagos, south-west of Nigeria. Material and Methods: This study was conducted on locally constructed inhomogeneous phantoms to measure mean organ doses to the head/neck, chest, and abdominopelvic regions from CT units in the Lagos metropolis, Nigeria. Lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) TLD was used for the measurement. Statistical analysis was performed by IBM SPSS (version 20). Results: Validation of the designed phantoms was below ± 20% kVp and mAs parameters among the CT units, which was statistically different with regard to the observed dose discrepancies. Generally, a one-way ANOVA showed that there was a statistically significant difference in the investigated mean organ dose (P = 0.043). The comparison of the obtained results from this study with those of other studies revealed that there was no statistically significant difference in the TLDs (P > 0.05). The maximum relative difference in the dose was 0.05). The maximum relative difference in the dose was Conclusion: The designed phantoms seemed to be useful for CT dose validation and could be used to validate simulation software in areas where readymade phantoms are not available.
    کلید واژگان
    Thermoluminescent-dosimeter
    Computed Tomography Phantom
    Organ
    organ dose
    Computed Tomography (CT)
    Medical Physics
    Radiation Detection & Measurement

    شماره نشریه
    2
    تاریخ نشر
    2019-03-01
    1397-12-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Department of Radiation Biology, Radiotherapy and Radiodiagnosis
    Department of Radiation Biology, Radiotherapy, Radiodiagnosis and Radiography, College of Medicine, Lagos University Teaching Hospital, Idi-Araba, Lagos, Nigeria
    Department of Radiation Biology, Radiotherapy, Radiodiagnosis and Radiography, College of Medicine, Lagos University Teaching Hospital, Idi-Araba, Lagos, Nigeria
    Department of Radiology, Medical Physics Unit, Federal medical Centre, Asaba.
    Department of Radiotion biology, radiotherapy, radiodiagnosis, Faculty of clinical sciences, University of Lagos.
    Department of Radiation Biology and Radiotherapy, College of Medicine, University of Lagos.
    Department of radiation biology, radiotherapy, radiodiagnosis, Faculty of clinical sciences, university of lagos, nigeria
    Radiation Biology, Radiotherapy, Radiodiagnosis, and Radiography, Clinical Sciences, College of Medicine, University of Lagos, Lagos State, Nigeria
    Department of radiation biology, radiotherapy, radiodiagnosis, faculty of clinical sciences, university of lagos, nigeria
    Department of Radiation Biology, Radiotherapy, Radiodiagnosis and Radiography, College of Medicine, Lagos University Teaching Hospital, Idi-Araba, Lagos, Nigeria

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2018.31815.1376
    http://ijmp.mums.ac.ir/article_11462.html
    https://iranjournals.nlai.ir/handle/123456789/324818

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب