Organ Dose Measurement in Computed Tomography Using Thermoluminescence Dosimeter in Locally Developed Phantoms
(ندگان)پدیدآور
Akpochafor, MichaelADENEYE, SAMUELHabeebu, MuhammadOMOJOLA, AKINTAYOAdedewe, NusiratAdedokun, AderonkeAdewa, DareAJIBADE, SUNDAYEkpo, VictorAweda, Mosesنوع مدرک
TextOriginal Paper
زبان مدرک
Englishچکیده
Introduction: Organ dose estimation using thermoluminescence dosimeter (TLD) is known to be a standard, although many other methods, such as simulation software, optically stimulated luminescent dosimeters, and photodiodes are still in use. This study aimed at directly measuring mean organ doses to the selected organs in the head/neck, chest, and abdominal regions from four computed tomography (CT) units in Lagos, south-west of Nigeria.
Material and Methods: This study was conducted on locally constructed inhomogeneous phantoms to measure mean organ doses to the head/neck, chest, and abdominopelvic regions from CT units in the Lagos metropolis, Nigeria. Lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) TLD was used for the measurement. Statistical analysis was performed by IBM SPSS (version 20).
Results: Validation of the designed phantoms was below ± 20% kVp and mAs parameters among the CT units, which was statistically different with regard to the observed dose discrepancies. Generally, a one-way ANOVA showed that there was a statistically significant difference in the investigated mean organ dose (P = 0.043). The comparison of the obtained results from this study with those of other studies revealed that there was no statistically significant difference in the TLDs (P > 0.05). The maximum relative difference in the dose was 0.05). The maximum relative difference in the dose was Conclusion: The designed phantoms seemed to be useful for CT dose validation and could be used to validate simulation software in areas where readymade phantoms are not available.
کلید واژگان
Thermoluminescent-dosimeterComputed Tomography Phantom
Organ
organ dose
Computed Tomography (CT)
Medical Physics
Radiation Detection & Measurement
شماره نشریه
2تاریخ نشر
2019-03-011397-12-10
ناشر
Mashhad University of Medical Sciencesسازمان پدید آورنده
Department of Radiation Biology, Radiotherapy and RadiodiagnosisDepartment of Radiation Biology, Radiotherapy, Radiodiagnosis and Radiography, College of Medicine, Lagos University Teaching Hospital, Idi-Araba, Lagos, Nigeria
Department of Radiation Biology, Radiotherapy, Radiodiagnosis and Radiography, College of Medicine, Lagos University Teaching Hospital, Idi-Araba, Lagos, Nigeria
Department of Radiology, Medical Physics Unit, Federal medical Centre, Asaba.
Department of Radiotion biology, radiotherapy, radiodiagnosis, Faculty of clinical sciences, University of Lagos.
Department of Radiation Biology and Radiotherapy, College of Medicine, University of Lagos.
Department of radiation biology, radiotherapy, radiodiagnosis, Faculty of clinical sciences, university of lagos, nigeria
Radiation Biology, Radiotherapy, Radiodiagnosis, and Radiography, Clinical Sciences, College of Medicine, University of Lagos, Lagos State, Nigeria
Department of radiation biology, radiotherapy, radiodiagnosis, faculty of clinical sciences, university of lagos, nigeria
Department of Radiation Biology, Radiotherapy, Radiodiagnosis and Radiography, College of Medicine, Lagos University Teaching Hospital, Idi-Araba, Lagos, Nigeria




