• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 2, Issue 2
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 2, Issue 2
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Development of A Head Docking Device for Linac-based Stereotactic Radiosurgery System to be Installed on Neptun 10 PC Linac

    (ندگان)پدیدآور
    Khoshbin Khoshnazar, A.Bahreyni Toosi, M. T.Hashemian, A.Bahreyni Toosi, M. H.Salek, R.
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.262 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction:  Stereotactic  radiosurgery  is  a  technique  for  the  treatment  of  intracranial  lesions  with  highly  collimated  x-ray  beam.  Linac-based  radiosurgery  is  currently  performed  by  two  techniques:  couch or pedestal mounted. In the first technique, a device is required to affix patient's head to a couch  and  moreover  to  translate  it  accurately.  Structure  of  such  a  device  constructed  by  the  authors  in  addition to the acceptance test which was performed to evaluate the device has been described in this  article.  Materials and Methods:  A head docking device has been designed and constructed according to the  geometry of linac's couch and desired functions. The device is completely made from aluminum and  consists  of  four  major  components:  attachment  bar,  lower  structure  with  four  movements,  upper  structure with two movements equipped with a lock, two handles and a mounting ring for stereotactic  frame. Translating accuracy, mechanical stability and isocentric accuracy were assessed in the frame of  acceptance test.  Results:  Translating  accuracy,  mechanical  stability  and  isocentric  accuracy  within  95%  confidence  intervals were found to be 1, 1.64 and 3.2 mm, respectively.  Discussion and Conclusion: According to AAPM report no.54 recommendation head docking device  should translate head with accuracy of 1 mm, the property which was met by the constructed device.  Moreover  considering  the  measured  isocentric  accuracy,  encompassing  mechanical  stability,  constructed device can confidently be used in stereotactic treatment.
    کلید واژگان
    Stereotactic radiosurgery
    head docking device
    translating accuracy
    mechanical stability
    Medical Physics
    Physics of Radiotherapy

    شماره نشریه
    2
    تاریخ نشر
    2005-06-01
    1384-03-11
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Assistant Professor, Medical Physics Dept., Golestan University of Medical Sciences, Golestan, Iran
    Professor, Medical Physics Research Center, Bu-Ali Research Institute, Mashhad University of Medical Sciences, Mashhad, Iran.
    Assistant Professor, Medical Physics Research Center, Bu-Ali Research Institute, Mashhad University of Medical Sciences, Mashhad, Iran.
    Professor, Medical Physics Research Center, Bu-Ali Research Institute, Mashhad University of Medical Sciences, Mashhad, Iran.
    Assistant Professor, Radiation Oncology Dept., Imam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2005.8110
    http://ijmp.mums.ac.ir/article_8110.html
    https://iranjournals.nlai.ir/handle/123456789/324754

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب