    Study the effect of source to diaphragm distance (SDD) on beam penumbra width of Gamma Knife machine model 4C using Monte Carlo simulation

    (ندگان)پدیدآور
    Mahmoudi, AtefehGeraily, GhazaleShirazi, AlirezaBakhshi, Masoume
    Thumbnail
    نوع مدرک
    Text
    Conference Proceedings
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Stereotactic radiosurgery (SRS) is one of the conformal radiotherapy methods and Gamma Knife is a non-invasive SRS technique to treat intracranial lesions with 201 Co- 60 sources without need to surgery and bleeding. Beam penumbra phenomenon leads to irradiation outside the field and normal tissues. Therefore, considering it is momentous to attain the acceptable treatment plan.   Materials and Methods: In this study, Gamma Knife unit was modeled using EGSnrc/BEAMnrc Monte Carlo code. SDD (Source to Diaphragm Distance) parameter that is one of the affecting factors on physical penumbra width was studied. For this purpose, SDD was increased for 4, 8, 14 and 18 mm collimator sizes in five steps and each step as much as one centimeter. Single beam profiles were calculated using EGSnrc/DOSXYZnrc code at isocentre depth in a cubic Plexiglas phantom. MATLAB and EXCEL software were used to plot profiles and measure physical penumbra width . Results: Based on the results, physical penumbra width (90%-50%) does not show a regular trend with increasing SDD. This may be attributed to scatter radiation which is due to the low distance between the Gamma Knife collimator end and phantom surface. Best results were observed for 4 and 8 mm collimators in 1 cm increase in which penumbra width decreased from 0.785 and 0.790 mm to 0.749 and 0.736 mm for 4 and 8 mm collimator sizes, respectively. Conclusion: It is recommended to increase SDD of Gamma Knife 4C around 1 centimeter to reduce penumbra width for small tumor sizes located near the critical nerves.
    کلید واژگان
    Gamma Knife Monte Carlo code SDD
    Physical penumbra

    شماره نشریه
    12
    تاریخ نشر
    2018-12-01
    1397-09-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Master Student, Medical Physics and Biomedical Engineering Department, Tehran University of Medical Sciences, Tehran, Iran
    Assistant Professor, Medical Physics and Biomedical Engineering, Department, Tehran University of Medical Sciences, Tehran, Iran
    Full Professor, Medical Physics and Biomedical Engineering, Department, Tehran University of Medical Sciences, Tehran, Iran
    Master Student, Medical Physics and Biomedical Engineering Department, Tehran University of Medical Sciences, Tehran, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2018.13027
    http://ijmp.mums.ac.ir/article_13027.html
    https://iranjournals.nlai.ir/handle/123456789/324649

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب