• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 15, Special Issue-12th. Iranian Congress of Medical Physics
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 15, Special Issue-12th. Iranian Congress of Medical Physics
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Measurement of Entrance Skin Dose and Effective Dose in The most Common Diagnostic radiology Examinations in Jiroft, Iran

    (ندگان)پدیدآور
    Goli Ahmadabad, FoadMomeni, Zeinabbijari, SalarBanaei, AminEbam, Susan
    Thumbnail
    نوع مدرک
    Text
    Conference Proceedings
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Medical uses of radiation have grown very rapidly over in the past two decades, medical uses represent the largest source of exposure to people, The most important methods in medical diagnosis are the useses of diagnostic radiology exams. Although the use of these methods is very beneficial for the treatment of patients, but ionizing radiation produces ion pairs, radicals, primary, secondary, and tertiary chemical reactions in body. The main purposes of this study were to investigate patient dose in common radiographic examinations   Materials and Methods: This study was performed in radiology centers and hospitals affiliated with Jiroft University of Medical Sciences, including Qaleh Ganj Hospital, Imam Khomeini Hospital, Kashani Hospital and 12th Farvardin Kahnoch Hospital. In each center, measurements are performed on at least 10 patients aged between 25 - 60 years for different imaging techniques including: Chest (PA), Pelvic (AP), Abdomen (AP), Skull (AP) and (LAT), Lumbar Spine (AP) and, Lumbar Spine (LAT) .ESD, ED were measured with T-LD 100 and PCXMC software, respectively Results: The average entrance skin dose (mGy) and effective dose (mSv) for the Chest (PA), Abdomen (AP), Pelvice (AP), Lumbar Spine (AP) and Lumbar Spine (LAT) and Skull (AP) and Skull (LAT) were (0.63-0.06), (2.34-0.32), (2.48-0.39), (3.33-0.34), (7.32-0.17), (2.9-0.02) and (1.81-0.01) respectively. Conclusion: The values indicate that the implementation of quality control and quality assurance programs in the radiology centers is necessary and all radiographic exams should be performed under lower doses with best quality of image.
    کلید واژگان
    Measurement of Entrance Skin Dose and Effective Dose in The most Common Diagnostic radiology Examinations in Jiroft
    Iran

    شماره نشریه
    12
    تاریخ نشر
    2018-12-01
    1397-09-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    School of Medicine, Jiroft Universitu of Medical Sciences, Jiroft, Iran
    Medical Physics Department, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
    Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
    Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
    Department of environmental Health engineering, Jiroft university of Medical Sciences, Jiroft, Iran.

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2018.13006
    http://ijmp.mums.ac.ir/article_13006.html
    https://iranjournals.nlai.ir/handle/123456789/324639

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب