نمایش مختصر رکورد

dc.contributor.authorSadremomtaz, Alirezaen_US
dc.contributor.authorTaherparvar, Peyvanden_US
dc.contributor.authorGholami, Sepidehen_US
dc.date.accessioned1399-07-09T07:34:25Zfa_IR
dc.date.accessioned2020-09-30T07:34:25Z
dc.date.available1399-07-09T07:34:25Zfa_IR
dc.date.available2020-09-30T07:34:25Z
dc.date.issued2018-12-01en_US
dc.date.issued1397-09-10fa_IR
dc.date.submitted2018-05-21en_US
dc.date.submitted1397-02-31fa_IR
dc.identifier.citationSadremomtaz, Alireza, Taherparvar, Peyvand, Gholami, Sepideh. (2018). Determination of the flux of a neutron radioisotope source through gold activation method. Iranian Journal of Medical Physics, 15(12), 310-310. doi: 10.22038/ijmp.2018.12965en_US
dc.identifier.issn2345-3672
dc.identifier.urihttps://dx.doi.org/10.22038/ijmp.2018.12965
dc.identifier.urihttp://ijmp.mums.ac.ir/article_12965.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/324601
dc.description.abstract<strong>Introduction</strong>: In recent years, the use of neutrons has increased in various fields such as medicine and industry. One of the important applications of neutrons is in medical research. Neutrons have greater linear energy transfer than gamma rays and are considered more dangerous radiation. Hence, the detection and determination of neutron dose is a very important and vital issue. For determination of neutron dose, measurement of its intensity or flux is essential. One of the ways of neutron flux determination is using of gold foil activation method. In this method, the activity of the irradiated foil is proportional to the neutron flux. The gold foil is activated by reaction 197Au (n,γ) 198Au because of the thermal neutron capture,. In the decay of activated gold, a gamma radiation of 411.8 keV is released with a probability of more than 95%, that By measuring the area below the peak associated with this energy, by the NaI(Tl) detector, the activity of gold and then the neutron flux is determined.   <strong>Materials and Methods:</strong> In this paper, an 18 carat gold foil was used to measure the flux of a neutron radioisotope source Ra-Be in the nuclear laboratory of the Faculty of Science of Guilan University.   <strong>Results:</strong> After irradiation, the gold foil was counted by NaI(Tl) detector and its flux was determined   <strong>Conclusion:</strong> Finally, by comparing the measured flux and the flux in the Ra-Be neutron source catalogue, it is resulted that the mentioned method has a good accuracy in determination of the flux of the neutron source.en_US
dc.languageEnglish
dc.language.isoen_US
dc.publisherMashhad University of Medical Sciencesen_US
dc.relation.ispartofIranian Journal of Medical Physicsen_US
dc.relation.isversionofhttps://dx.doi.org/10.22038/ijmp.2018.12965
dc.subjectneutron sourceen_US
dc.subjectneutron activationen_US
dc.subjectgold foilen_US
dc.subjectNaI(Tl) detectoen_US
dc.titleDetermination of the flux of a neutron radioisotope source through gold activation methoden_US
dc.typeTexten_US
dc.typeConference Proceedingsen_US
dc.contributor.departmentDepartment of physics, University of Guilan, Rasht, Guilan, Email: Sadremomtaz@yahoo.co.uken_US
dc.contributor.departmentDepartment of physics, University of Guilan, Rasht, Guilan, Email: p.taherparvar@guilan.ac.iren_US
dc.contributor.departmentFaculty of Science, University of Guilan, Rasht, Guilan, Email: Gholamisepideh6@gmail.comen_US
dc.citation.volume15
dc.citation.issue12
dc.citation.spage310
dc.citation.epage310


فایل‌های این مورد

فایل‌هااندازهقالبمشاهده

فایلی با این مورد مرتبط نشده است.

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد