• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 15, Special Issue-12th. Iranian Congress of Medical Physics
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 15, Special Issue-12th. Iranian Congress of Medical Physics
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Rabbit internal dosimetry for iodine-131 using GATE Monte Carlo simulation code: a preclinical trial

    (ندگان)پدیدآور
    Yavari, ShimaGeramifar, ParhamFallahpoor, MaryamAbbasi, Mehrshad
    Thumbnail
    نوع مدرک
    Text
    Conference Proceedings
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: One of the main concerns in administration of radiotracers, especially in therapeutic arm, is the amount of delivered dose to the different organs. Individual variations of anatomy, physiology and underlying pathology in the patients lead to alteration of administered activity. In the current study we preclinically applied internal dosimetry using an animal model   Materials and Methods: The SPECT/CT imaging of a rabbit 24 hours after administration of 288μci Iodine-131 was done. Biodistribution of radiotracer was obtained from SPECT, and the CT was used to define attenuation map and the target volume of interest (VOIs). Dosimetry calculations were performed with GATE Monte Carlo code and S-values for beta and gamma radiation of different organs were calculated.   Results: The S-values of thyroid as target organ are 1.09×10-4(mGy/MBq/sec) for beta and 1.05×10- 5 for gamma radiation. And S-values of kidneys, lungs, spine, and heart as critical organs are 1.10×10-5, 1.58×10-5, 7.62×10-6, 6.75×10-6 for beta, respectively and 3.9×10-6, 2.69×10-6, 2.63×10-6, 3.27×10-6 for gamma, respectively Conclusion: The internal dosimetry is applicable clinically. The response to therapy would be increased and the side effect would be minimized if the prescription using patient specific dosimetry is optimized.
    کلید واژگان
    Monte Carlo Simulation
    SPECT/CT
    Internal Dosimetry
    Iodine-131

    شماره نشریه
    12
    تاریخ نشر
    2018-12-01
    1397-09-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Department of Nuclear Medicine, Vali-asr Hospital Tehran University of Medical Sciences, Tehran, Iran
    Department of Nuclear Medicine, Shariati Hospital Tehran University of Medical Sciences, Tehran, Iran
    Department of Nuclear Medicine, Vali-asr Hospital Tehran University of Medical Sciences, Tehran, Iran
    Department of Nuclear Medicine, Vali-asr Hospital Tehran University of Medical Sciences, Tehran, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2018.12866
    http://ijmp.mums.ac.ir/article_12866.html
    https://iranjournals.nlai.ir/handle/123456789/324528

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب