• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 15, Special Issue-12th. Iranian Congress of Medical Physics
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 15, Special Issue-12th. Iranian Congress of Medical Physics
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Treatment couch positioning uncertainties using an EPID-based method

    (ندگان)پدیدآور
    Afzalifar, AzamMowlavi, Ali AsgharMohammadi, MohammadAbdollahi, Sara
    Thumbnail
    نوع مدرک
    Text
    Conference Proceedings
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: The accuracy of patient positioning plays an important role for radiotherapy tasks. Short and automated Quality Assurance (QA) programs are becoming one of the challenging tasks in Radiotherapy. The current study, investigates the accuracy of treatment couch positioning with four degrees of freedom (4DoF) using a fast and accurate method based on an image acquired using an electronic portal imaging device (EPID). Materials and Methods: A Siemens medical linear accelerator equipped with an a-Si EPID was used to capture portal images. An accurate EPID QA phantom (PTW EPID QC Phantom®) and a proper in-house algorithm were used. The phantom has different sections to assess EPID image quality. Preliminary tests including Mechanical performance of the EPID positioning, EPID sensitivity and the code response from image processing point of view were investigated through several deviations deliberately created to evaluate translational and rotational displacements of treatment couch. Loading effect on treatment couch was also investigated. Results: The results of EPID preliminary tests and in-house code reliability were within tolerances expected. The mean deviations of tests for (4DoF) treatment couch were 0.25°±0.10˚, 0.428±0.112 mm, 0.428±0.112 mm and 0.286±0.112 mm for rotational, longitudinal, lateral and vertical shifts, respectively. The results of incline caused by a 130kg loading on the couch showed that the proposed method is a reliable and fast to find the uncertainties occurred for treatment couch positioning. Conclusion: As a part of linac QA program, treatment couch tests including translational and rotational motions under unloaded/loaded conditions were performed. The corresponding errors for table positioning including minimum detectable rotational and translational displacements, and couch sagging effect under loaded conditions were evaluated using an EPID. Creating one major test for the whole assessments for couch checks, fast and accurate and no labour intensive procedure, and electronic portal image instead of film and other imagers can be addressed as advantages of the method proposed.
    کلید واژگان
    EPID
    Treatment Couch
    Quality Assurance

    شماره نشریه
    12
    تاریخ نشر
    2018-12-01
    1397-09-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Physics Department, School of Sciences, Hakim Sabzevari University, Sabzevar, Iran.
    Physics Department, School of Sciences, Hakim Sabzevari University, Sabzevar, Iran. ICTP, Associate federation Scheme, Medical Physics Field, Trieste, Italy.
    Department of Medical Physics, Royal Adelaide Hospital, Adelaide, SA 5000 AUSTRALIA. School of Physical Sciences, the University of Adelaide, SA 5005 AUSTRALIA. Department of Medical Physics, Reza Radiotherapy and Oncology Center, Mashhad, Iran
    Department of Medical Physics, Reza Radiotherapy and Oncology Center, Mashhad, Iran.

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2018.12856
    http://ijmp.mums.ac.ir/article_12856.html
    https://iranjournals.nlai.ir/handle/123456789/324518