نمایش مختصر رکورد

dc.contributor.authorFarokhi Moghadam, Faridehen_US
dc.date.accessioned1399-07-09T07:34:06Zfa_IR
dc.date.accessioned2020-09-30T07:34:06Z
dc.date.available1399-07-09T07:34:06Zfa_IR
dc.date.available2020-09-30T07:34:06Z
dc.date.issued2018-12-01en_US
dc.date.issued1397-09-10fa_IR
dc.date.submitted2018-05-21en_US
dc.date.submitted1397-02-31fa_IR
dc.identifier.citationFarokhi Moghadam, Farideh. (2018). On Presentation of Optimal Treatment Plan in Radiotherapy of Parotid Cancer: A Comparison of Nine Techniques in Three Dimensional Conformal Radiation Therapy. Iranian Journal of Medical Physics, 15(12), 210-210. doi: 10.22038/ijmp.2018.12827en_US
dc.identifier.issn2345-3672
dc.identifier.urihttps://dx.doi.org/10.22038/ijmp.2018.12827
dc.identifier.urihttp://ijmp.mums.ac.ir/article_12827.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/324502
dc.description.abstract<strong>Introduction</strong>: Today, radiotherapy combined with surgery in the treatment of parotid tumors widely are used specially for high grade parotid tumors. One of concern and challenge issue of radiotherapy is that the treatment of these tumors with irregular surface due to the presence of external ear and region of different physical electron density (air cavities, dense bone, soft tissue). Therefore, offering an optimal treatment plan to the desired results in terms of dose distribution factors to adequate target coverage and protect critical structures surrounding OARs is so important. This study aimed to achieve an optimal treatment plan using low-energy electrons, as well as different modes of electrons and photons will be considered. Also the effect of bolus to achieve the optimal treatment plan is performed. <strong>Materials and Methods:</strong> CT of parotid patients during 2012 to 2014 is used. Twelve patients were evaluated by TPS Core plan, 3D dose distribution and using of dose-volume histogram (DVH), nine techniques were evaluated: a.6MV photons, 3-fields AP(wedge), PA(wedge), lateral(open), b. unilateral 10 Mev electrons, c. unilateral 14 Mev electrons, d. Mixed beam technique using 6MV photon and 10 Mev electron(1:4 weighting), e. Mixed beam technique using 6MV photon and 14 Mev electron(1:4 weighting), f. unilateral 10 Mev electrons with bolus (0.5 cm bolus is used), g. unilateral 14 Mev electrons with bolus (0.5 cm bolus is used), h. Mixed beam technique using 6MV photon and 10 Mev electron (1:4 weighting) with Bolus (0.5 cm bolus is used), i. Mixed beam technique using 6MV photon and 14Mev electron (1:4 weighting) with Bolus (0.5 cm bolus is used) <strong>Results:</strong> Using of DVH to appraise, the dose to OARs are 0 for techniques 6MV photons, (3-fields), unilateral 10 Mev electrons with and without Bolus, unilateral 14 Mev electrons with & without Bolus <strong>Conclusion:</strong> The highest conformal and homogeneity index and near to 1 were for 6MV photons, 3-fields, unilateral 14 Mev electrons with and without Bolus, mixed beam technique using 6MV photon and 14 Mev electron with and without Bolus.en_US
dc.languageEnglish
dc.language.isoen_US
dc.publisherMashhad University of Medical Sciencesen_US
dc.relation.ispartofIranian Journal of Medical Physicsen_US
dc.relation.isversionofhttps://dx.doi.org/10.22038/ijmp.2018.12827
dc.subjectBolusen_US
dc.subjectParotid Gland Canceren_US
dc.subjectDose Volume Histogramen_US
dc.subjectThree Dimensional Conformal Radiation Therapy (3DCRT)en_US
dc.titleOn Presentation of Optimal Treatment Plan in Radiotherapy of Parotid Cancer: A Comparison of Nine Techniques in Three Dimensional Conformal Radiation Therapyen_US
dc.typeTexten_US
dc.typeConference Proceedingsen_US
dc.contributor.departmentMedical Physics Department, Faculty of Medicine & engineering, Shahid beheshti University of Medical Sciences, Tehran, Iran. Email: F.FAROKHI93@GMAIL.COM, Tel: +98 9120570453en_US
dc.citation.volume15
dc.citation.issue12
dc.citation.spage210
dc.citation.epage210


فایل‌های این مورد

فایل‌هااندازهقالبمشاهده

فایلی با این مورد مرتبط نشده است.

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد