• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 15, Special Issue-12th. Iranian Congress of Medical Physics
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 15, Special Issue-12th. Iranian Congress of Medical Physics
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Comparison of three different techniques in parotid gland tumors using three dimensional conformal radiation therapy

    (ندگان)پدیدآور
    Farokhi Moghadam, Farideh
    Thumbnail
    نوع مدرک
    Text
    Conference Proceedings
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Background: Radiotherapy of parotid tumors is achieved by different radiotherapy techniques. So they deliver the dose to organs at risk such as contralateral parotid, temporal lobe & spinal cord. The consequences of high dose to OARs are xerostomia, Temporal lobe necrosis and loss of hearing. Purpose: The aim of this study was to compare different treatment techniques for parotid gland tumors using three different techniques to find the optimal technique which demonstrates sufficient target coverage and preserving of surrounding normal tissue at 3DCRT treatment of parotid cancer Materials and Methods: The CT-scans of ten parotid patients were used. The target volume and OARs were contoured and after 3D dose distribution and using of dose-volume histogram (DVH), three different plans were done and were compared: A. Ipsilateral oblique wedge photon 6MV pair with bolus B. Photons, 3-fields AP(wedge), PA(wedge), lateral(open), C. Mixed beam: 6MV photon ipsilateral oblique wedge pair & 14Mev electron with bolus (1:4) Results: Target coverage was suitable for techniques B and C. Technique c showed the best homogeneity and conformity index at target volume. The dose to OARs was lower than other techniques. On other hand, technique A demonstrated ineligible homogeneity within PTV & the higher dose to OARs than other techniques.   Conclusion: mixed beam: 6MV photon ipsilateral oblique wedge pair & 14Mev electron with bolus is an optimal treatment plan for treatment of parotid cancer patients in such way than other techniques.
    کلید واژگان
    Radiotherapy
    Parotid gland cancer patients
    DVH
    loss of hearing

    شماره نشریه
    12
    تاریخ نشر
    2018-12-01
    1397-09-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Medical Physics Department, Faculty of Medicine & engineering, Shahid beheshti University of Medical Sciences, Tehran, Iran. Tel: +989120570453, Email: f.farokhi93@gmail.com

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2018.12826
    http://ijmp.mums.ac.ir/article_12826.html
    https://iranjournals.nlai.ir/handle/123456789/324501

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب