    Investigation of physical penumbra definition in IMRT applications

    (ندگان)پدیدآور
    Alipour, HajarHadad, KamalFaghihi, Reza
    Thumbnail
    نوع مدرک
    Text
    Conference Proceedings
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Because of small size of the beamlets in IMRT, physical penumbra is one of the important dosimetric parameters and small changes in the penumbra will have a great impact on the results. The physical penumbra width is defined as the lateral distance between two specified isodose curves at a specified depth of phantom. In this study, after demonstrating the inconsistency of conventional physical penumbra definition for non-uniform MLC fields, two new dosimetric parameters proposed, those are intended to be suitable for MLC fields   Materials and Methods: Physical penumbra evaluation was obtained using IAEA phase space data for a Varian IX and EGSnrc Monte Carlo code package. The homogenous water phantom is located at SSD=100 cm. Results: With conventional definition, physical penumbra widths for all MLC setups on right and left sides of isodose curves (parallel to X and Y axes) are not equal. With the proposed dosimetric parameters, the effect of MLC setup is taken into consideration. Conclusion: The intended purpose from physical penumbra in its conventional definition is not satisfied for non-uniform MLC setups. For such cases, the newly defined surface penumbra and uniformity index are demonstrated to be more suitable and indicative of the field non-uniformity. It is also shown that for an idle treatment planning system, the uniformity index approaches unity.
    کلید واژگان
    Physical Penumbra Dosimetric Parameters DOSXYZnrc EGSnrc
    CTV

    شماره نشریه
    12
    تاریخ نشر
    2018-12-01
    1397-09-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Department of Nuclear Engineering, Shiraz University, Faculty of Mechanical Engineering, Email: halipour@shirazu.ac.ir Tel: +98 9385741949
    1Department of Nuclear Engineering, Shiraz University, Faculty of Mechanical Engineering,
    Department of Nuclear Engineering, Shiraz University, Faculty of Mechanical Engineering,

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2018.12674
    http://ijmp.mums.ac.ir/article_12674.html
    https://iranjournals.nlai.ir/handle/123456789/324460

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب