    Dosimetric and Radiobiological Evaluation of Multiparametric MRI-guided Dose Painting in radiotherapy of Prostate Cancer

    (ندگان)پدیدآور
    Abedi, IrajTavakkoli, Mohammad BagherJabbari, KeyvanAmouheidari, AlirezaYadegar-far, Ghasem
    Thumbnail
    نوع مدرک
    Text
    Conference Proceedings
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Radiotherapy is one of the treatment options for locally advanced prostate cancer, however with standard radiation doses it is not always very effective. One of the strategies to improve the efficiency of radiotherapy is increasing the dose. In this study to increase tumor local control rates a new radiotherapy method, known as dose painting (DP) was investigated.   Materials and Methods: Twenty-four consecutive patients with locally advanced prostate cancer who underwent an MP-MRI (T2w, DWI, DCE, MRS) scan, before a diagnostic biopsy from September 2015 to April 2016 were invited to take part in this study. Results: The TCP values for 3D-CRT, IMRT and DP techniques were 45%, 56% and 77%, respectively. The DP technique had a 37.5% and 71% higher TCP than IMRT and 3D-CRT, and these differences were statistically significant (P = 0.001). The mean NTCP values of the OARs for 3D-CRT, IMRT, and DP showed that there were statistically significant differences between them in three plans (p = 0.01). Conclusion: Dose painting by contours using MP-MRI is technically feasible. This study evaluated biological modeling based on both MP-MRI defined sub-volumes and pathologically defined sub-volumes. The MP-MRI guided dose painting results in the better TCP/ NTCP than 3D-CRT and IMRT.
    کلید واژگان
    Radiobiological Evaluation
    Dose Painting by Conturing
    Multiparametric MRI

    شماره نشریه
    12
    تاریخ نشر
    2018-12-01
    1397-09-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Faculty Member of Medical Physics, Isfahan University of Medical Sciences, Isfahan, Iran.
    Professor of Medical Physics Faculty, Isfahan University of Medical Sciences, Isfahan, Iran.
    Associate Professor of Medical Physics Faculty, Isfahan University of Medical Sciences, Isfahan, Iran.
    Radiation oncologist, Isfahan Milad Hospital, Isfahan, Iran.
    Associate Professor of Health Faculty, Isfahan University of Medical Sciences, Isfahan, Iran.

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2018.12619
    http://ijmp.mums.ac.ir/article_12619.html
    https://iranjournals.nlai.ir/handle/123456789/324418

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب