• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 15, Special Issue-12th. Iranian Congress of Medical Physics
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 15, Special Issue-12th. Iranian Congress of Medical Physics
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A New Method for Estimating of Patient Effective Dose in Computed Tomography Based on Body Mass Index: Performance of the Method in Abdomen-Pelvic Examination

    (ندگان)پدیدآور
    Jamshidi, Mohammad HosseinDeevband, Mohammad RezaTahmasebi Birgani, Mohammad JavadYadollahpour, AliTahmasebi, Morteza
    Thumbnail
    نوع مدرک
    Text
    Conference Proceedings
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: The CT Provide high quality images, especially in low-contrast soft tissue, are another advantage. Along with all the benefits that the CT scans which have, the patient dose of this modality is much greater than other methods. As a result, medical imaging community must ensure that the benefits of radiological examination for each patient are higher than related risks. Although the CT has a small percentage of radiological examination, but it has a large contribution on the exposure to the community. the purpose of the present study was to investigate how the introduction of MDCT scanners and patient-size-dependent imaging protocols have affected patient doses and propose a simple method to predict an estimation of the organ and effective doses by using BMI and mAeff. The nobility of the present scientific study was to investigate how the introduction of MDCT scanners and patient-size-dependent imaging protocols have affected patient doses. Materials and Methods: Demographic data of each patient were recorded as well as data from a CT scan of the abdomen and pelvic of 52 patients were studied. For assessment of patient and effective doses, the information related to the scan in ImPACT software was applied. The results are analyzed and regression was used in order to examine the relation between the results of the scan data in MATLAB environment. Results: The research findings showed that the received dose to the most patients is the same as determined by the ICRP103. An average of the effective dose(6mSv) was less than predicted amount by ICRP103. To estimate the effective dose of the body, according to the patient's BMI, an equation was obtained [Effective Dose (mSv) = 0.257 BMI - 0.637]. The results from this equation are corresponded to the calculated dose by Impact (R2>0.95). In addition, the method was proposed to predict the parameters of mAeff and DLP resulted from the related scan. 0.95). In addition, the method was proposed to predict the parameters of mAeff and DLP resulted from the related scan. [mAeff (mGy.cm) = 4.73 BMI -19.81 , DLP(mGy.cm) = 17.17 BMI -56.36]. Conclusion: According to the results of this study, authors proposed a good alternative to estimate the effective dose according to BMI instead of ImPACT calculations for scanners and scanning conditions as well as a method to predict the effective dose by using the parameters of the CT system and BMI without being radiated on the patients.
    کلید واژگان
    Patient’s dose Effective dose Impact

    شماره نشریه
    12
    تاریخ نشر
    2018-12-01
    1397-09-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Department of Radiologic Technology, Faculty of Paramedicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
    Department of Medical Physics and Biomedical engineering, Shahid-Beheshti University of Medical Sciences, Iran
    Department of Radiation Therapy, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Iran Department of Radiology, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Iran
    Department of Radiation Therapy, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Iran
    .

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2018.12617
    http://ijmp.mums.ac.ir/article_12617.html
    https://iranjournals.nlai.ir/handle/123456789/324416

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب