نمایش مختصر رکورد

dc.contributor.authorRahmani, Fereshteen_US
dc.contributor.authorMohsenzadeh, Behzaden_US
dc.contributor.authorKaveh, Zeinaben_US
dc.contributor.authorDeevband, Mohammad Rezaen_US
dc.contributor.authorazimi, Leilaen_US
dc.date.accessioned1399-07-09T07:33:46Zfa_IR
dc.date.accessioned2020-09-30T07:33:46Z
dc.date.available1399-07-09T07:33:46Zfa_IR
dc.date.available2020-09-30T07:33:46Z
dc.date.issued2018-12-01en_US
dc.date.issued1397-09-10fa_IR
dc.date.submitted2018-05-21en_US
dc.date.submitted1397-02-31fa_IR
dc.identifier.citationRahmani, Fereshte, Mohsenzadeh, Behzad, Kaveh, Zeinab, Deevband, Mohammad Reza, azimi, Leila. (2018). Construction of an Equivalent Chest Homogeneous Phantom for Evaluation of Image Quality in Pediatric Radiography. Iranian Journal of Medical Physics, 15(12), 99-99. doi: 10.22038/ijmp.2018.12427en_US
dc.identifier.issn2345-3672
dc.identifier.urihttps://dx.doi.org/10.22038/ijmp.2018.12427
dc.identifier.urihttp://ijmp.mums.ac.ir/article_12427.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/324392
dc.description.abstract<strong>Introduction</strong>:<br /> The purpose of this study is to build homogeneous equivalent phantom chest in order to provide the necessary ability for checking the image quality in radiographic tests in four age groups of children in terms of the most recent age group categorization ICRP103. This phantom provides the features of weakness and discrepancies similar to body and can be considered as a good alternative for the geometrical body equivalent Phantom.<br /> <strong>Materials and Methods:</strong><br /> This geometrical body equivalent phantom has been employed in order to measure the absorbed dose using Monte Carlo calculation code. Using this phantom in Monte Carlo space in which x-ray tube system has been simulated as well makes it possible to analyze the weaknesses and x-ray discrepancies. The Phantom is made of Plexiglas.<br /> <strong>Results:</strong><br /> Validity of the tests with lower than 5% error, deep dose in Monte Carlo and the experimental space as well collectively confirms the simulator program. After the process of simulation, the homogeneous phantoms chest equivalent in children were produced with different thicknesses for different age groups. Simulated as well makes it possible to analyze the weaknesses and x-ray discrepancies.<br /> <strong>Conclusion:</strong><br /> The phantom designed in this study can be used to evaluate the dose of children in different age groups, Also, using image quality control tools such as contrast, resolution, etc. in this phantom can be used to evaluate the parameters of the image quality in the actual condition of the patient's body. In this study, An attempt was made to provide a new method for the construction of a chest equivalent phantom that would include all age groups.en_US
dc.languageEnglish
dc.language.isoen_US
dc.publisherMashhad University of Medical Sciencesen_US
dc.relation.ispartofIranian Journal of Medical Physicsen_US
dc.relation.isversionofhttps://dx.doi.org/10.22038/ijmp.2018.12427
dc.subjectPatient doseen_US
dc.subjectGeometric Phantom Equivalent- Bodyen_US
dc.subjectChest Phantom Pediatric Radiographyen_US
dc.titleConstruction of an Equivalent Chest Homogeneous Phantom for Evaluation of Image Quality in Pediatric Radiographyen_US
dc.typeTexten_US
dc.typeConference Proceedingsen_US
dc.contributor.departmentDepartment of Medical Physics and Biomedical engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences and Health Services, Tehran, Iranen_US
dc.contributor.departmentDepartment of Medical Physics and Biomedical engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences and Health Services, Tehran, Iranen_US
dc.contributor.departmentDepartment of Medical Physics and Biomedical engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences and Health Services, Tehran, Iranen_US
dc.contributor.departmentDepartment of Medical Physics and Biomedical engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences and Health Services, Tehran, Iran TEL: 09123044609, E-mail: mdeevband@sbmu.ac.iren_US
dc.contributor.departmentDeparteman of imaging of Velayat hospital, University of medical science, Qazvin, Iranen_US
dc.citation.volume15
dc.citation.issue12
dc.citation.spage99
dc.citation.epage99


فایل‌های این مورد

فایل‌هااندازهقالبمشاهده

فایلی با این مورد مرتبط نشده است.

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد