    چکیده
    Introduction: Breast conserving surgery followed by adjuvant radiotherapy (RT) of the whole breast is accepted as the treatment of choice in early stage breast cancer. Due to breast irregularities, it is difficult to access homogenous dose distribution with conventional techniques. Currently, it is possible to use varied breast irradiation techniques, such as field- in-field (FIF), to apply a more homogenous distribution of doses within target volumes, and organs at risk (OAR) sparing which lead to achieve better treatment outcome. This study aimed to compare conventional and FIF techniques dosimetrically Materials and Methods: Twenty patients with early-stage breast cancer underwent computed tomography (CT) with a 16 Slice CT simulator; datasets were transferred to the treatment planning system (TPS) via a digital imaging communications in medicine (DICOM). Two different treatment plans were created for each patient by the same medical physicist: a wedge base (conventional) plan and a FIF plan. Then, dosimetric and monitor unit (MU) results were compared. Results: Dosimetric indices in the planning target volume (PTV) were more satisfying with the FIF technique than with three dimensional-conformal RT (3D-CRT). FIF reduced the maximum doses of PTV and MU. In addition, the FIF technique reduced doses to the heart (in left-side irradiation cases) and ipsilateral lung by 7% and 8%, respectively. FIF also significantly reduced V40 (volume receiving 40 Gy) of heart in left side breast irradiation. V20 of lung (volume receiving 20 Gy), and also doses to the contralateral lung did not differ significantly. Conclusion: FIF can produce more homogenous doses within the PTV, and reduce doses to the OAR. Moreover, by using the FIF technique in breast irradiation, MUs required for therapy are significantly decreased compared with that required by 3D-CRT.
    کلید واژگان
    Field In Field
    3D Conformal
    Radiotherapy
    Wedge
    Breast Irradiation
    OAR Dose

    شماره نشریه
    12
    تاریخ نشر
    2018-12-01
    1397-09-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Department of Medical Physics, Faculty of Medicine, Mashhad University of medical sciences, Mashhad, Iran Medical physics Research Center, Faculty of Medicine, Mashhad University of medical sciences, Mashhad, Iran
    Department of Medical Physics, Faculty of Medicine, Mashhad University of medical sciences, Mashhad, Iran Medical physics Research Center, Faculty of Medicine, Mashhad University of medical sciences, Mashhad, Iran Department of Radiotherapy and Oncology, Imam Reza Hospital, Mashhad, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2018.11864
    http://ijmp.mums.ac.ir/article_11864.html
    https://iranjournals.nlai.ir/handle/123456789/324312

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب