    Quality assessment of conventional X-ray diagnostic equipment by measuring X-ray exposure and tube output parameters in Great Khorasan Province, Iran

    (ندگان)پدیدآور
    Hashemi, MohammadBayani Roodi, ShahramShahedi, FatemeMomennezhad, MahdiZare, HodaGholamhosseinian, Hamid
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.113 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Regular implementation of quality control (QC) program in diagnostic X-ray facilities may affect both image quality and patient radiation dose due to the changes in exposure parameters. Therefore, this study aimed to investigate the status of randomly selected conventional radiographic X-ray devices installed in radiology centers of Great Khorasan Province, Iran, to produce the data needed to formulate QC policies, which are essential to ensure the accuracy of the diagnosis while minimizing the radiation dose. Material and Methods: This cross-sectional study was performed using a calibrated Piranha multi-purpose detector to measure QC parameters in order to unify X‐ray imaging practices using international guidelines. The QC parameters included voltage accuracy, voltage reproducibility, exposure time accuracy, exposure time reproducibility, tube output linearity with time andmilliampere (mA), and tube output reproducibility. Data analysis procedures were performed based on the type of an X-ray generator, which has not been reported in previous studies. Results: The results showed that the implementation of high-frequency X-ray generators were more advantageous compared to alternative current generators, due to their efficient, better accuracy, linearity, and reproducibility. Conclusion: The survey revealed that the QC program was not conducted at regular intervals in some of the investigated radiology centers, mostly because of inadequate enforcement by national regulatory authorities for implementation of QC program.
    کلید واژگان
    Diagnostic Equipment
    Quality Control
    Radiography
    Medical Physics
    Physics of Diagnostics Radiology

    شماره نشریه
    1
    تاریخ نشر
    2019-01-01
    1397-10-11
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Medical Physics Research Center, Mashhad University of Medical Sciences, Mashahd, Iran.
    Medical Physics Research Center, Mashhad University of Medical Sciences, Mashahd, Iran.
    Department of Radiology, School of Paramedical Sciences, Torbat Heydariyeh University of Medical Sciences, Torbat Heydariyeh, Iran.
    Medical Physics Research Center, Mashhad University of Medical Sciences, Mashahd, Iran.
    Medical Physics Research Center, Mashhad University of Medical Sciences, Mashahd, Iran.
    Medical Physics Research Center, Mashhad University of Medical Sciences, Mashahd, Iran.

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2018.33719.1417
    http://ijmp.mums.ac.ir/article_11746.html
    https://iranjournals.nlai.ir/handle/123456789/324283

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب