    Local Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran

    (ندگان)پدیدآور
    Zarghani, Hassanbahreyni, Mohammadtaghi
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    976.1کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Diagnostic reference level (DRL) is a useful tool for the promotion of optimization. The national DRLs (NDRLs) are useful, brief, and robust guidelines for optimizing radiation protection in a country. The aim of this study was to extract the local DRLs (LDRLs) for some common radiologic examination in Sabzevar county. Materials and Methods: There are eight radiology departments in Sabzevar County, Iran. The entrance skin dose (ESD) distributions were determined by use of thermoluminescence dosimeter (TLD) chips for 10 standard projections (i.e., anterioposterior [AP] abdomen, AP and posteroanterior [PA] chest, AP and lateral [LAT] lumbar spine, AP pelvis, cervical AP, cervical LAT, as well as AP and LAT skull). The third quartiles of the measured ESDs were compared with the previously published data. Results: In the present study, the third quartile of the measured ESDs for the patients undergoing specific examination were selected as LDRLs. The calculated LDRLs for the chest PA, chest AP, lumbar spine PA, lumbar spine LAT, pelvis AP, abdomen AP, cervical AP, cervical LAT, skull PA, and skull LAT were 0.54, 0.64, 1.99, 3.83, 1.47, 2.15, 0.54, 0.78, 1.22, and 1.01 mGy, respectively. Conclusion: Our results were compared with the DRLs reported in Iran, UK, and Japan as well as those reported by the National Radiological Protection Board (NPRB) for the UK. The ESDs obtained in this study for the chest PA, cervical AP, cervical LAT, AP and LAT skull, abdomen AP, pelvis AP, lumbar PA, and lumbar LAT examinations did not exceed the DRL values reported by NPRB.
    کلید واژگان
    Diagnostic X-Ray
    Radiography
    Radiation Dosage
    Radiation Protection
    Medical Physics
    Physics of Diagnostics Radiology
    Radiation Detection & Measurement

    شماره نشریه
    1
    تاریخ نشر
    2018-01-01
    1396-10-11
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Cardiovascular Diseases Research Center, Birjand University of Medical Sciences, Birjand, Iran
    Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2017.19211.1237
    http://ijmp.mums.ac.ir/article_9316.html
    https://iranjournals.nlai.ir/handle/123456789/324277

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب