    چکیده
    Introduction: Microdosimeters are helpful for dose equivalent measurement in unknown radiation fields. The favorable physical and mechanical properties of the detector-grade chemical vapor deposition diamond materials have made the diamond microdosimeters suitable candidate for radioprotection applications in space. The purpose of this work is the investigation of the dose equivalent response of a typical diamond microdosimeter with laser-induced graphitized electrodes for use in space radiation fields. Materials and Methods: The Geant4 Monte Carlo simulation toolkit was applied to simulate the particle transport within the microdosimeter, and to determine the mean chord length and the dose equivalent response of the microdosimeter, based on the lineal energy dependent quality factor.   Results: The linear stopping power of the protons and alpha particles with energies higher than 5 MeV and 10 MeV respectively can be estimated within20% of deviation using the microdosimeter response. The fluence to dose equivalent conversion coefficients calculated affirms that there is an adequate agreement between the calculated coefficients and other research group results. Conclusion: The reasonable agreement between the dose equivalents calculated in this study and the results reported by other researchers confirmed that this type of microdosimeter could be a promising candidate suitable for the measurement of the dose equivalent in space radiation fields.
    کلید واژگان
    Diamond Microdosimeter
    Dose-Equivalent Response
    Monte Carlo
    Simulation
    Medical Physics
    Radiation Detection & Measurement

    شماره نشریه
    1
    تاریخ نشر
    2018-01-01
    1396-10-11
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Radiation Applications Research School, Nuclear Science and Technology Research Institute, AEOI, Tehran, Iran
    Radiation Applications Research School, Nuclear Science and Technology Research Institute, AEOI, P.O.Box: 11365-3486, Tehran, Iran
    Laser and Optics Research School, Nuclear Science and Technology Research Institute, AEOI, P.O.Box: 11365-8486, Tehran, Iran
    Energy Engineering and Physics Faculty, Amirkabir University of Technology, P.O.Box: 15875-4413, Tehran, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2017.24503.1242
    http://ijmp.mums.ac.ir/article_9338.html
    https://iranjournals.nlai.ir/handle/123456789/324275

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب