    An Investigation of the Dose Distribution from LDR Ir-192 Wires in the Triangular Implants of the Paris System using Polymer Gel Dosimetry

    (ندگان)پدیدآور
    Rahimi, AzizollahHashemi, BijanZahmatkesh, Mohammad HassanJaberi, RaminSheibani, Shahab
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    680.1کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Polymer gels are modern dosimeters providing three dimensional dose distributions. These dosimeters can be used in brachytherapy in which the tumor dimension is relatively small and the dose gradient is high. In this study, the ability of the MAGICA polymer gel was investigated for assessing the absolute dose values as well as the dose distribution of low dose rate (LDR) Ir-192 wires in interstitial brachytherapy based in triangular implants of the Paris system. Material and Methods: A suitable phantom was made from Perspex. Glass tubes were used as the external tubes for holding the Ir-192 wires in the phantom. The MAGICA polymer gel was made and placed in the phantom. The phantom and the calibration tubes were irradiated using LDR Ir-192 wires and a Co-60 teletherapy unit respectively. They were subsequently imaged using an MRI scanner. The R2 (=1/T2) maps were extracted from several sequential T2-weighted MRI images. The dose values resulting from the polymer gel measurements at the reference points were compared with those from the common calculation method at the same points. In addition, the isodose curves resulting from gel dosimetry were compared with those from a brachytherapy treatment planning system (Flexiplan). Results: The average of the dose values measured with the gel at the reference points was 62.75% higher than those calculated at the same points. Investigating the isodose curves revealed that the maximum distance to agreement (DTAmax) between the isodoses resulting from the gel and those obtained from the treatment planning system was less than 3 mm at different dose levels. Discussion and Conclusion: Although the MAGICA gel indicates a higher absolute dose value than those calculated commonly, it can give the relative dose values accurately. Therefore, it can be recommended to be used for the assessment of dose distributions for the treatment of tissues as well as quality control of the treatment planning systems.
    کلید واژگان
    Brachytherapy
    MAGICA
    Normoxic Polymer Gel
    Paris System
    Polymer Gel Dosimetry
    Interstitial
    Medical Physics
    Physics of Radiotherapy
    Radiation Detection & Measurement

    شماره نشریه
    4
    تاریخ نشر
    2010-12-01
    1389-09-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    MSc Student of Medical Physics, Tarbiat Modares University, Tehran, Iran.
    Associate Professor, Medical Physics Dept., Tarbiat Modares University, Tehran, Iran.
    Assistant Professor, Novin Medical Radiation Institute, Tehran, Iran.
    Physicist, Cancer Institute, Department of Radiotherapy and Oncology, Imam Khomeini Hospital, Tehran, Iran.
    Assistant Professor, Nuclear Sciences Research Center, Nuclear Science and Technology Research Center, Tehran, Iran.

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2010.7242
    http://ijmp.mums.ac.ir/article_7242.html
    https://iranjournals.nlai.ir/handle/123456789/324167

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب