• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 8, Issue 3
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 8, Issue 3
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Optimization of 3D Planning Dosimetry in a Breast Phantom for the Match Region of Supraclavicular and Tangential Fields

    (ندگان)پدیدآور
    Nourollahi, SomayehAllahverdi, MahmoudEsfahani, MahbodAghili, MehdiChangizi, Vahid
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    706.6کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: The complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (PTV) result in perturbations in dose distribution. This problem can result in overdosage or underdosage in the match region of the three treatment fields. The purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and tangential fields, utilizing Gafchromic EBT film for dosimetry. Material and Methods: In this study, a slab phantom was designed with lung- and heart-equivalent inhomogetenities. Our measurements were carried out using Gafchromic EBT film. Irradiations were performed using the 6 MV photon beam of a Varian 2100 Clinac linear accelerator. Three-dimensional treatment planning and dose calculations were carried out using the RT Dose Plan software. The conventional method with source-to-skin distance match and a 3D method with source-to-axis distance match under different combinations of parameters such as gantry, collimator and couch rotations as well as asymmetric fields were utilized. Results: The results demonstrated differences between the 3D and conventional techniques. The best results in the match region were observed using the 3D method with asymmetric technique (maximum area of overlap = 0.43 cm2, depth of overlap = 3.55 cm, and average width of overlap = 0.75 cm). Discussion and Conclusion: This study shows that the EBT film is a suitable tool for two-dimensional distribution dosimetry and relative dose measurements. The study shows difficulties in achieving a homogenous dose distribution in the match region of supraclavicular and tangential fields and also demonstrates the effects of setup parameters on matching of treatment fields.
    کلید واژگان
    Breast Radiotherapy
    Dose Inhomogenity
    EBT Film Dosimetry
    Match Region
    Medical Physics
    Physics of Radiotherapy
    Radiation Detection & Measurement

    شماره نشریه
    3
    تاریخ نشر
    2011-09-01
    1390-06-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    M.Sc.in Medical Physics, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran
    Associate Professor, Medical Physics Dept., Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran
    M.Sc.in Medical Physics, Radiotherapy Dept., Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran
    Assistant Professor, Radiotherapy Dept., Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran
    Assistant Professor, Radiology Technology Dept., Faculty of Allied Medical Sciences, Tehran University of Medical Sciences, Tehran, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2011.7231
    http://ijmp.mums.ac.ir/article_7231.html
    https://iranjournals.nlai.ir/handle/123456789/324163

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب