    Design of an Elastic Arthroplastic Disc Optimized under Different Loads

    (ندگان)پدیدآور
    Ghouchani, AzadehKatouzian, Hamid RezaRavari, Mohammad
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    579.3کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Due to limitations of current treatments for degenerative disc disease, arthroplastic methods to repair the diseased disc have been proposed. The artificial disc is a mobile implant for degenerative disc replacement that attempts to lessen the degeneration of the adjacent elements following interbody fusion procedures. Because the success of artificial disc replacement depends on maintenance or restoration of the mechanical function of the intervertebral disc, it is useful to study the initial mechanical performance of the disc after implantation in the spine.   Materials and Methods: A three-dimensional finite element model of the L3–L4 disc was analyzed. The model took into account the material nonlinearities and it imposed different loading conditions. In this study, we validated the model by comparison of its predictions with several sets of experimental data; we determined the optimal Young's modulus as well as the Poissan ratios for the artificial disc under different loading conditions. Results: The artificial disc was subjected to three loading conditions: 1) compression, 2) bending and 3) torsion. In each case, optimum elastic parameters were determined. Then, by using the root mean square method, optimum parameters for all loading conditions (and therefore minimum error) were calculated. Discussion and Conclusion: The results of this study suggest that a well-designed elastic arthroplastic disc preferably has Young's modulus values of 18.63 MPa and 1.19 MPa for the annulus and nucleus sections, respectively. Elastic artificial disc with such properties can then achieve the goal of restoring the disc height and mechanical function of a normal disc under different loading conditions.
    کلید واژگان
    Low back pain
    Intervertebral disc
    optimization
    Finite Element
    Arthroplasty
    Medical Engineering
    Medical Physics

    شماره نشریه
    2
    تاریخ نشر
    2011-06-01
    1390-03-11
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    M.Sc. in Biomedical Engineering, Biomedical Engineering Dept., Amir Kabir University of Technology, Tehran, Iran.
    Associate Professor, Biomedical Engineering Dept., Amir Kabir University of Technology, Tehran, Iran.
    Instructor, Biomedical Engineering Dept., Mashhad Branch, Islamic Azad University, Mashhad, Iran.

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2011.7217
    http://ijmp.mums.ac.ir/article_7217.html
    https://iranjournals.nlai.ir/handle/123456789/324155

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب