    Monte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography

    (ندگان)پدیدآور
    Pirayesh Islamian, JalilBahreyni Toossi, Mohammad TaghiMomennezhad, MahdiZakavi, Seyyed RasoolSadeghi, Ramin
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    375.5کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program was used for simulation of a Siemen's dual-head variable angle scintillation gamma camera. Planar and SPECT scanning of a 99mTc source and a Jaszczak phantom for varying thicknesses of Perspex slabs, as a backscatter media, were analyzed using the photopeak and scatter windows. Simulated planar images and reconstructed tomographic images were evaluated qualitatively, by two nuclear medicine specialists, and quantitatively, by Structural Similarity (SSIM) Index. Results In the 99mTc photopeak window, no significant change in total counts due to backscatter material was measured. In the scatter windows, scattering was overestimated compared with a simulated backscatter free SPECT system. For instance, at a thickness of 10 cm, total counts of a 99mTc source detected in the 72 keV windows eventually doubled with increasing backscatter material, compared with the situation without backscatter material. The backscatter contribution plateaued when more than 7 cm of scatter material was placed but there were optimized results for a backscatter thickness of 4.5 cm. Better image quality for the thickness was confirmed by the results of eye interpretation and also by SSIM algorithm. Conclusion Backscatter should be taken into account, particularly in model-based scatter correction methods in SPECT for an accurate simulation system optimization.
    کلید واژگان
    Backscatter Media
    Image Quality
    Resolution
    SIMIND Monte Carlo
    Single Photon Emission Computed Tomography
    Medical Application of Computer Simulation
    Medical Physics
    Physics of Nuclear Medicine

    شماره نشریه
    1
    تاریخ نشر
    2013-03-01
    1391-12-11
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Medical Physics Department, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran.
    Medical Physics Research Center, Medical Physics Department, Mashhad University of Medical Sciences, Mashhad, Iran
    Nuclear Medicine Department, Imam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran
    Nuclear Medicine Department, Imam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran
    Nuclear Medicine Department, Imam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2013.920
    http://ijmp.mums.ac.ir/article_920.html
    https://iranjournals.nlai.ir/handle/123456789/324123

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب