    Volume-guaranteed Ventilation Versus Pressure-controlled Ventilation in Preterm Infants with Respiratory Distress Syndrome: A Randomized Controlled Trial

    (ندگان)پدیدآور
    Krishna, GokulAnn Skariah, TishaLewis Edward, Leslie
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    830.1کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: This study was targeted toward comparing volume-guaranteed (VG) ventilation with conventional pressure-controlled (PC) ventilation in preterm infants with respiratory distress syndrome (RDS) in terms of the facilitation of weaning and extubation and occurrence of complications, such as pneumothorax, intraventricular hemorrhage (IVH), retinopathy of prematurity (ROP), necrotizing enterocolitis (NEC). Methods: This single-center randomized controlled trial was conducted on neonates who were mechanically ventilated in the Neonatal Intensive Care Unit of Kasturba Hospital Manipal Udupi, Karnataka, India. Infants with the gestational age (GA) of 27-34 weeks with RDS requiring mechanical ventilation in the first week of life were randomized to receive either SIMV-PC or SIMV-VG ventilation. Infants were stratified into two GA groups of 27-30 and 31-34 weeks. Sealed opaque envelope was used to randomize the infants into two treatment modalities. Sample size was calculated as 120 and 60 in each treatment group. Results: A total of 115 neonates were enrolled. The mean GA and birth weight of the treatment groups were 31±2.3 weeks and 1230±374 g, respectively, and 70% of them received antenatal steroids. As the primary outcome variable, the total duration of ventilation was 8 h (range: 3-17) (median and IQR) in the SIMV-PC group and 6 h (range: 3-13) in the SIMV-VG group (P=0.366). Stratified analysis of neonates with the GA of > 31-34 weeks showed a significant difference between the VG and PC ventilation groups regarding the duration of ventilation. 31-34 weeks showed a significant difference between the VG and PC ventilation groups regarding the duration of ventilation. Conclusion: There was a decrease in the duration of ventilation in VG ventilation, compared to that in PC ventilation at a higher GA. The leak was the major issue with VG ventilation in the lower GA group.
    کلید واژگان
    RDS
    SIMV-PC
    SIMV-VG

    شماره نشریه
    2
    تاریخ نشر
    2019-06-01
    1398-03-11
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Department of Respiratory Therapy, School of Allied Health Sciences, Manipal, Udupi P.O, Karnataka, India
    Department of Respiratory Therapy, School of Allied Health Sciences, Manipal, Udupi P.O, Karnataka, India
    Head of Neonatal Intensive Care Unit, Department of Paediatrics, Kasturba Medical College,Manipal, Udupi P.O, Karnataka, India

    شاپا
    2251-7510
    2322-2158
    URI
    https://dx.doi.org/10.22038/ijn.2018.33533.1490
    http://ijn.mums.ac.ir/article_12054.html
    https://iranjournals.nlai.ir/handle/123456789/323371

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب