    Analytical Performance and Quality Control of a Glucose Monitor System

    (ندگان)پدیدآور
    Azari Yam, AileenMohammadi Torbati, Peyman
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    205.8کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Research
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within certain intervals of the reference method, regression analysis, and difference plot. We used operational process specification charts to determine the probability that different QC rules would detect an analytical error. In addition, we assessed the quality on the sigma scale. Results: This meter met International Organization for Standardization's criteria but not the American Diabetes Association's stringent criteria. The monitor produced precise readings throughout the concentration range and results correlated closely with the reference method. The measured total error was 6.39% (less than allowable total error of 10%). The method reached 6 sigma at glucose levels of 6.66 and 18.87 mmol/L and a sigma of 3 to 4 at glucose level of 2.49. Repeatability and intermediate precision were acceptable. Discussion: We concluded that the overall performance of this instrument is reasonable but in hypoglycemic range, multiple control rules and control materials are required to assure the desired quality is achieved.
    کلید واژگان
    Blood Glucose Self Monitoring
    Diabetes Mellitus
    Point of Care Systems

    شماره نشریه
    1
    تاریخ نشر
    2011-01-01
    1389-10-11
    ناشر
    Iranian Society of Pathology Farname Inc.
    سازمان پدید آورنده
    Dept. of Genetics, Tehran University of Medical Sciences, Tehran, Iran
    Dept. of Pathology, Shahid Beheshti University of Medical Sciences, Tehran, Iran

    شاپا
    1735-5303
    2345-3656
    URI
    http://ijp.iranpath.org/article_8522.html
    https://iranjournals.nlai.ir/handle/123456789/319281

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب