    Efficacy of Increasing Focus to Film Distance (FFD) for Patient’s Dose and Image Quality in Pediatric Chest Radiography

    (ندگان)پدیدآور
    Karami, VahidZabihzadeh, MansourDanyaei, AmirShams, Nasim
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    365.0کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: Increasing the x-ray focus to film distance (FFD) has been advocated as an effective method to reduce the patients' radiation dose. The aim of this study was to investigate the efficacy of this technique in patients' dose and image quality in pediatric chest x-ray.Material and methods: Sixty pediatric patients were x-ray imaged at FFDs of 100 and 130 cm. Dose measurements were performed using thermo-luminescent dosimeters (GR200). The quality of images was independently assessed using the anatomical criteria recommended by the European guidelines.Results: Increasing the FFD from 100 to 130 cm has reduced the entrance skin dose (ESD) of patients by 32.2% (p 0.05).Conclusion: Increased FFD to 130 cm reduce the pediatric radiation dose with no significant changes in image quality.
    کلید واژگان
    Chest radiography
    Focus to film distance (FFD)
    Pediatric
    Radiation Protection

    شماره نشریه
    9
    تاریخ نشر
    2016-09-01
    1395-06-11
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
    Department of Medical Physics, School of Medicine, Student Research Committee, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran. Department of Clinical Oncology, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
    Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
    Department of Oral and Maxillofacial Radiology, School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

    شاپا
    2345-5047
    2345-5055
    URI
    https://dx.doi.org/10.22038/ijp.2016.7319
    http://ijp.mums.ac.ir/article_7319.html
    https://iranjournals.nlai.ir/handle/123456789/317734

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب