• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Asian Pacific Journal of Cancer Prevention
    • Volume 20, Issue 2
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Asian Pacific Journal of Cancer Prevention
    • Volume 20, Issue 2
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Domain-Based Analysis of Colon Polyp in CT Colonography Using Image-Processing Techniques

    (ندگان)پدیدآور
    K N, ManjunathPC, SiddalingaswamyPrabhu, GK
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.324 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Articles
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: The purpose of the research was to improve the polyp detection accuracy in CT Colonography (CTC)through effective colon segmentation, removal of tagged fecal matter through Electronic Cleansing (EC), and measuringthe smaller polyps. Methods: An improved method of boundary-based semi-automatic colon segmentation with theknowledge of colon distension, an adaptive multistep method for the virtual cleansing of segmented colon based onthe knowledge of Hounsfield Units, and an automated method of smaller polyp measurement using skeletonizationtechnique have been implemented. Results: The techniques were evaluated on 40 CTC dataset. The segmentationmethod was able to delineate the colon wall accurately. The submerged colonic structures were preserved withoutsoft tissue erosion, pseudo enhanced voxels were corrected, and the air-contrast layer was removed without losingthe adjacent tissues. The smaller polyp of size less than validated qualitatively and quantitatively. Segmented colons were validated through volumetric overlap computation,and accuracy of 95.826±0.6854% was achieved. In polyp measurement, the paired t-test method was applied to comparethe difference with ground truth and at α=5%, t=0.9937 and p=0.098 was achieved. The statistical values of TPR=90%,TNR=82.3% and accuracy=88.31% were achieved. Conclusion: An automated system of polyp measurement has beendeveloped starting from colon segmentation to improve the existing CTC solutions. The analysis of domain-basedapproach of polyp has given good results. A prototype software, which can be used as a low-cost polyp diagnosis tool,has been developed.
    کلید واژگان
    Computer-aided detection and diagnosis
    Segmentation
    shape analysis
    colon polyp
    domain based approach
    Diagnostic radiology

    شماره نشریه
    2
    تاریخ نشر
    2019-02-01
    1397-11-12
    ناشر
    West Asia Organization for Cancer Prevention (WAOCP)
    سازمان پدید آورنده
    Department of Computer Science and Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India.
    Department of Computer Science and Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India.
    Department of Electronics and Communication, Manipal University, Jaipur, India.

    شاپا
    1513-7368
    2476-762X
    URI
    https://dx.doi.org/10.31557/APJCP.2019.20.2.629
    http://journal.waocp.org/article_82397.html
    https://iranjournals.nlai.ir/handle/123456789/31178

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب