• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Nuclear Medicine
    • Volume 25, Issue 2
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Nuclear Medicine
    • Volume 25, Issue 2
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Characterization of low, medium and high energy collimators for common isotopes in nuclear medicine: A Monte Carlo study

    (ندگان)پدیدآور
    Razavi, Seyed HosseinKalantari, FarazBagheri, MahmoudNamiranian, NasimNafisi-Moghadam, RezaMardanshahi, AlirezaEmami-Ardekani, AlirezaSobhan Ardekani, Mohammadrazavi ratki, Seid kazem
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    703.5کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction:In an ideal parallel-hole collimator, thickness of septal material should be sufficient to stop more than 95% of incident photons. However, some photons pass the septa without interaction or experience scattering before they reach the detector. In this study, we determined different contribution of collimator responses consist of geometrical response, septal penetration (SP) and scattering (SC) for low, medium and high energy collimators. Methods: A point source of activity with common energies in diagnostic nuclear medicine and three different collimators were simulated using SIMIND Monte Carlo code. Results: For Low Energy High Resolution (LEHR) collimator, SP was increased from 7% in 140 keV to 30% in 167keV and more than 75% in energies higher than 296keV. SC also was increased from 4% in 98keV to more than 15% in energies higher than 167keV and reached to its maximum (26%) in 296keV. For Medium Energy All Purpose (MEAP) collimator, SP was suddenly increased from 6% in 186keV to 28% for 296keV and more than 50% for higher energies. SC was also increased from 4% in energies below 186keV to 15% in 296keV and about 30% for higher energies. For High Energy (HE) collimator, SP was about 20% for 364keV photons. SC was 15% for 364keV photons and only 65% of photons were geometrically collimated. Conclusion: Our results showed that even by using nominally suitable collimators, there are considerable SC and SP that influence the quantitative accuracy of planar and SPECT images. The magnitude of geometrical response, SC and SP depend on collimator geometric structure and photons energy.
    کلید واژگان
    Collimator responses
    Monte Carlo
    Geometric response
    Septal penetration
    Scatter
    Medical Physics, Dosimetry, Instrumentation and Radiobiology

    شماره نشریه
    2
    تاریخ نشر
    2017-07-01
    1396-04-10
    ناشر
    Research Center for Nuclear Medicine (Tehran University of Medical Sciences)
    سازمان پدید آورنده
    Department of Oral and Maxillofacial Radiology, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
    Department of Radiation Oncology, UT Southwestern, Medical Center, Dallas, TX, USA
    Department of Medical Physics, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
    Yazd Diabetes Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
    Department of Radiology, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
    Department of Radiology, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran
    Research Center for Nuclear Medicine, Tehran University of Medical Sciences, Tehran, Iran
    Department of Radiology, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
    Department of Radiology, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran

    شاپا
    1681-2824
    2008-2509
    URI
    http://irjnm.tums.ac.ir/article_26411.html
    https://iranjournals.nlai.ir/handle/123456789/300510

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب