    A study on differentiation of extra-cardiac activity by Slit Slat collimation in Single Photon Emission Computed Tomography

    (ندگان)پدیدآور
    Darkhor, ParvanehMahmoudian, BabakGharapapagh, EsmaeilZakavi, Seyed RasoulPirayesh Islamian, Jalil
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    3.019 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Myocardial perfusion SPECTby 99mTc-Sestamibi and 99mTc-Tetrofosmin radiopharmaceuticals usually presents a false significant increase in the radiotracer uptake in the inferior myocardium due to the uptake in organs such as liver, bowel, stomach and biliary system. The present study evaluated a suitable Slit angle for differentiating extra-cardiac activities by Slit Slat collimation. Methods: The Siemens E.CAM gamma camera equipped with a Low Energy High Resolution (LEHR) collimator was simulated with the Simulating Medical Imaging Nuclear Detectors (SIMIND) Monte Carlo program. Following the verification of the simulation, a Slit Slat collimator was simulated for SPECT imaging of a NURBS-based Cardiac Torso (NCAT) phantom with different Slit angels ranged from 0 to 30 degrees. The reconstructed images were qualitatively assessed with blinded observer method by three nuclear medicine specialists. Results:The improved differentiation of the bowel activity from the cardiac was obtained by a Slit-Slat collimator with the Slit angle of 7 degree. While for gastric activity differentiation an angle of 15 degree for the Slit was useful. Conclusion: The results showed that Slit Slat collimation with 7 and 15 Slit angle provide a suitable differentiation of the bowel and gastric activities from the cardia, respectively.
    کلید واژگان
    myocardium
    NCAT
    SPECT, Slit Slat collimator
    SIMIND Monte Carlo
    Medical Physics, Dosimetry, Instrumentation and Radiobiology
    Nuclear Medicine

    شماره نشریه
    1
    تاریخ نشر
    2018-01-01
    1396-10-11
    ناشر
    Research Center for Nuclear Medicine (Tehran University of Medical Sciences)
    سازمان پدید آورنده
    Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
    Departments of Radiology, Tabriz University of Medical Sciences, Tabriz, Iran
    Departments of Radiology, Tabriz University of Medical Sciences, Tabriz, Iran
    Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
    Departments of Medical Physics, Tabriz University of Medical Sciences, Tabriz, Iran

    شاپا
    1681-2824
    2008-2509
    URI
    http://irjnm.tums.ac.ir/article_29035.html
    https://iranjournals.nlai.ir/handle/123456789/300344

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب