نمایش مختصر رکورد

dc.contributor.authorSalimi-Khorshidi, Alien_US
dc.contributor.authorAbolghasemi, Hoseinen_US
dc.contributor.authorGhannadi, Mohammaden_US
dc.date.accessioned1399-07-09T05:33:47Zfa_IR
dc.date.accessioned2020-09-30T05:33:47Z
dc.date.available1399-07-09T05:33:47Zfa_IR
dc.date.available2020-09-30T05:33:47Z
dc.date.issued2010-03-01en_US
dc.date.issued1388-12-10fa_IR
dc.identifier.citationSalimi-Khorshidi, Ali, Abolghasemi, Hosein, Ghannadi, Mohammad. (2010). Presenting an Empirical Correlation for Maximum Sauter Mean Diameter in a Spray Extraction Column. Journal of Chemical and Petroleum Engineering, 43(2)doi: 10.22059/jchpe.2010.20969en_US
dc.identifier.issn2423-673X
dc.identifier.issn2423-6721
dc.identifier.urihttps://dx.doi.org/10.22059/jchpe.2010.20969
dc.identifier.urihttps://jchpe.ut.ac.ir/article_20969.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/284424
dc.description.abstractBased on the importance of drops' behavior in liquid-liquid extraction, the maximum sauter mean drop diameter has been investigated and correlated in a counter-current spray extraction column with two chemical systems. Spargers were set of nozzles in all experiments. Studying the effects of several parameters on drops size, some correlations were estimated by the last available version of software “Eviews”. Finally, the best empirical correlation was selected based on lowest error and highest conformity with the experimental data. It’s notable that, in this paper, the maximum sauter mean drop diameter was investigated and correlated for first time in a spray extraction column. Comparing final selected correlation with experimental data, it’s observed that the correlation mentioned above has an error about 4.22% with empirical data that shows the good accuracy of this correlation.en_US
dc.format.extent300
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherUniversity of Tehranen_US
dc.relation.ispartofJournal of Chemical and Petroleum Engineeringen_US
dc.relation.isversionofhttps://dx.doi.org/10.22059/jchpe.2010.20969
dc.titlePresenting an Empirical Correlation for Maximum Sauter Mean Diameter in a Spray Extraction Columnen_US
dc.typeTexten_US
dc.contributor.departmentدانشگاه تهرانen_US
dc.contributor.departmentدانشگاه تهرانen_US
dc.contributor.departmentدانشگاه صنعتی امیرکبیرen_US
dc.citation.volume43
dc.citation.issue2


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد