• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Cardio-Thoracic Medicine
    • Volume 3, Issue 2
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Cardio-Thoracic Medicine
    • Volume 3, Issue 2
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Spirometric Parameters: Hemodialysis Compared to Peritoneal Dialysis

    (ندگان)پدیدآور
    Rezaeetalab, FaribaZeraati, AbbasaliFadaeian, Amir HoseinAkbarirad, MinaAzami, GhazalehShahrzad MohamadZadeh Lari, ShahrzadAsnaashari, Amir Mohamad Hashem
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1006.کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Renal failure affects the mechanical and the ventilatory function of the lungs. A few studies have evaluated the ventilatory and pulmonary function in dialysis patients. The present study aimed to compare Pulmonary Function Test (PFT) results in patients undergoing Hemodialysis (HD) and Peritoneal Dialysis (PD). Materials and Methods: We conducted a cross-sectional study on 50  patients with hemodialysis (HD) and 50 cases with PD who  underwent PFT in Ghaem and Imam Reza hospitals Mashhad, Iran from November 2010 to July 2012. Spirometric parameters including forced expiratory volume in 1s (FEV1), FEV1/forced vital capacity (FVC), forced expiratory flow 25-75% (FEF) and peak expiratory flow (PEF) were compared between the two groups of patients. Results: Approximately 68% of the HD patients, 66% of the PD patients, and 67% of all the studied cases showed a normal spirometric pattern. Moreover, there were no significant differences between the two groups considering the mean of the aforementioned spirometric parameters(restrictive ,obstructive pattern) (P=0.969). However, an insignificant inverse correlation was observed between the duration of dialysis with FEV1 (r=0.381, P=0.008), FVC (r=-0.298, P=0.04), FEF 25-75% (r=0.43, P=0.003), PEF (r= 0.349, P=0.02) and FEV1/FVC (r=-0.363, P=0.01,) in the HD patients and between the patients' age with FEV1/FVC (r=0.03, P=0.02) in the PD patients. Conclusion: This study showed no significant difference in pulmonary function in hemo and peritoneal dialysis,so according this result ,both of the dialysis had the same affect on the lung function.
    کلید واژگان
    hemodialysis
    Peritoneal dialysis
    Pulmonary function tests

    شماره نشریه
    2
    تاریخ نشر
    2015-05-01
    1394-02-11
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Pulmonologist, Lung Disease Research Center, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Ir
    Nephrologist, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
    Fellowship of Cardiology, Faculty of Medicine, Mashhad University of Medical Sciences, Iran
    Resident of Internal Medicine, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
    Resident of Internal Medicine, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
    Pulmonologist, Cardio-Thoracic Surgery & Transplant Research Center, Emam Reza Hospital, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
    Pulmonologist, Lung Disease Research Center, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran

    شاپا
    2345-2447
    2322-5750
    URI
    https://dx.doi.org/10.22038/jctm.2015.4376
    http://jctm.mums.ac.ir/article_4376.html
    https://iranjournals.nlai.ir/handle/123456789/280624

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب