• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Dental Materials and Techniques
    • Volume 4, Issue 3
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Dental Materials and Techniques
    • Volume 4, Issue 3
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

    (ندگان)پدیدآور
    Arab, HamidRezaMoeintaghavi, AmirSargolzaei, NaserMokhtari, MajidRezaDerhami, MohammadArab, SepidehMoosavi, Javad
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    168.1کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3i implant (3i Implant Innovation, Palm Beach Gardens, FL, USA). The evaluations were performed one year after loading. Materials and Methods: A total of 39 implants (23 external hex, 16 internal hex) were placed randomly in 23 patients (10 male, 13 female) by a submerged approach. None of patients had compromised conditions or parafunctional habits. At placement and at one year after loading, periapical radiographs were taken via the parallel method from the implant sites. Results: Crestal bone loss was -0.712±0.831 mm in implants with an internal hex connection and -0.139±0.505 mm in implants with an external hex connection (P≤0.05). No correlation was found between crestal bone loss and parameters such as age, gender, jaw, implant location (anterior, premolar, or molar), implant diameter, or implant length. Conclusions: Crestal bone loss was greater in patients with internal hex 3i implants than in those with external implants. Similar results in other clinical factors were found between the groups.
    کلید واژگان
    Implant
    crestal bone loss
    internal and external hex connections
    Periodontics

    شماره نشریه
    3
    تاریخ نشر
    2015-09-01
    1394-06-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Associate Professor of Periodontics, Dental Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
    Professor of Periodontics, Dental Materials Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
    1 Associate Professor of Periodontics, Dental Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
    Assistant Professor of Periodontics, Dental Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
    Prosthodontist
    Dentist
    Dentist

    شاپا
    2322-4150
    2252-0317
    URI
    https://dx.doi.org/10.22038/jdmt.2015.4598
    http://jdmt.mums.ac.ir/article_4598.html
    https://iranjournals.nlai.ir/handle/123456789/280213

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب