    Estimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation Code FLUKA

    (ندگان)پدیدآور
    Sinha, APatni, HDixit, BPainuly, NSingh, N
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    481.6کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Research
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: Most preclinical studies are carried out on mice. For internal dose assessment of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies, SAF values are estimated using older standard human organ compositions and values for limited source target pairs.Objective: SAF values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 keV were evaluated for the Digimouse voxel phantom incorporated in Monte Carlo code FLUKA. The organ sources considered in this study were lungs, skeleton, heart, bladder, testis, stomach, spleen, pancreas, liver, kidney, adrenal, eye and brain. The considered target organs were lungs, skeleton, heart, bladder, testis, stomach, spleen, pancreas, liver, kidney, adrenal and brain. Eye was considered as a target organ only for eye as a source organ. Organ compositions and densities were adopted from International Commission on Radiological Protection (ICRP) publication number 110.Results: Evaluated organ masses and SAF values are presented in tabular form. It is observed that SAF values decrease with increasing the source-to-target distance. The SAF value for self-irradiation decreases with increasing photon energy. The SAF values are also found to be dependent on the mass of target in such a way that higher values are obtained for lower masses. The effect of composition is highest in case of target organ lungs where mass and estimated SAF values are found to have larger differences.Conclusion: These SAF values are very important for absorbed dose calculation for various organs of a mouse.
    کلید واژگان
    Specific Absorbed Fraction
    Digimouse Voxel Phantom
    Monte Carlo Simulation
    FLUKA

    شماره نشریه
    4
    تاریخ نشر
    2016-12-01
    1395-09-11
    ناشر
    Shiraz University of Medical Sciences
    سازمان پدید آورنده
    Faculty of Physical Science, Shri Ramswaroop Memorial University, Lucknow
    Bhabha Atomic Research Center, Mumbai- 400085
    Faculty of Physical Sciences, Shri Ramswaroop Memorial University, Lucknow- 225003
    Department of Radiotherapy, King George Medical University, Lucknow-226003
    Department of Radiotherapy, King George Medical University, Lucknow-226003

    شاپا
    2251-7200
    URI
    https://jbpe.sums.ac.ir/article_43233.html
    https://iranjournals.nlai.ir/handle/123456789/26688

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب