    Evaluation of Effective Sources in Uncertainty Measurements of Personal Dosimetry by a Harshaw TLD System

    (ندگان)پدیدآور
    Hosseini Pooya, SMOrouji, T
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    426.3کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Research
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance.Objective: In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD.Method: These sources are included; inhomogeneity of TLDs sensitivity, variabil- ity of TLD readings due to limited sensitivity and background, energy dependence, directional dependence, non-linearity of the response, fading, dependent on ambient temperature / humidity and calibration errors, which may affect on the dose responses. Some parameters which influence on the above sources of uncertainty are studied for Harshaw TLD-100 cards dosimeters as well as the hot gas Harshaw 6600 TLD reader system.Results: The individual uncertainties of each sources was measured less than 6.7% in 68% confidence level. The total uncertainty was calculated 17.5% with 95% confi- dence level.Conclusion: The TLD-100 personal dosimeters as well as the Harshaw TLD-100 reader 6600 system show the total uncertainty value which is less than that of admis- sible value of 42% for personal dosimetry services.
    کلید واژگان
    TLD
    Uncertainty
    Personal Dosimetry
    TLD Reader
    Dose
    Response

    شماره نشریه
    2
    تاریخ نشر
    2014-06-01
    1393-03-11
    ناشر
    Shiraz University of Medical Sciences
    سازمان پدید آورنده
    Iran Nuclear Regulatory Authority, Tehran, Iran
    Iran Nuclear Regulatory Authority, Tehran, Iran

    شاپا
    2251-7200
    URI
    https://jbpe.sums.ac.ir/article_43161.html
    https://iranjournals.nlai.ir/handle/123456789/26616

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب