    Comparative Measurements of Radon Concentration in Soil Using Passive and Active Methods in High Level Natural Radiation Area (HLNRA) of Ramsar

    (ندگان)پدیدآور
    Amanat, BKardan, MRFaghihi, RHosseini Pooya, SM
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.512 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Research
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: Radon and its daughters are amongst the most important sources of natural exposure in the world. Soil is one of the significant sources of radon/thoron due to both radium and thorium so that the emanated thoron from it may cause increased uncertainties in radon measurements. Recently, a diffusion chamber has been designed and optimized for passive discriminative measurements of radon/thoron concentrations in soil.Objective: In order to evaluate the capability of the passive method, some comparative measurements (with active methods) have been performed.Method: The method is based upon measurements by a diffusion chamber, including two Lexan polycarbonate SSNTDs, which can discriminate the emanated radon/ thorn from the soil by delay method. The comparative measurements have been done in ten selected points of HLNRA of Ramsar in Iran. The linear regression and correlation between the results of two methods have been studied.Results: The results show that the radon concentrations are within the range of 12.1 to 165 kBq/m3 values. The correlation between the results of active and passive methods was measured by 0.99 value. As well, the thoron concentrations have been measured between 1.9 to 29.5 kBq/m3 values at the points.Conclusion: The sensitivity as well as the strong correlation with active measurements shows that the new low-cost passive method is appropriate for accurate seasonal measurements of radon and thoron concentration in soil.
    کلید واژگان
    Radon
    Ramsar
    Passive Detectors
    SSNTD

    شماره نشریه
    4
    تاریخ نشر
    2013-12-01
    1392-09-10
    ناشر
    Shiraz University of Medical Sciences
    سازمان پدید آورنده
    Department of physics, Payame Noor University, Po Box 19395-3697, Tehran, Iran
    Radiation Application School, Nuclear Sciences and Technology Institute, Tehran, Iran
    Radiation Research Center, Shiraz University, Shiraz, Iran
    Radiation Application School, Nuclear Sciences and Technology Institute, Tehran, Iran

    شاپا
    2251-7200
    URI
    https://jbpe.sums.ac.ir/article_43153.html
    https://iranjournals.nlai.ir/handle/123456789/26607

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب