    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Assessment of Photoplethysmography Method in Extraction of Hemoglobin Concentration

    (ندگان)پدیدآور
    Azarnoosh, MDoostdar, H
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.076 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Research
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: The importance of continuous monitoring along with rapid and accurate notification of changes in blood components such as hemoglobin concentration, especially in acute situations, encourages researchers to use non-invasive methods for measuring.Objective: This study was aimed to investigate the correlation between hemoglobin concentration and photoplethysmogram (PPG) and the possibility of measuring it by an optical method.Material and Methods: In this applied study, a PPG signal was simultaneously recorded at four different wavelengths for thirty subjects who were referred to the laboratory for a hemoglobin concentration test. After calibrating the special recording probe with a standard pulse oximeter system and applying the required preprocessing on the obtained signals, the peak-to-peak value of PPG signals was extracted. Finally, the correlation between the peak-to-peak value of the signal at a certain wavelength and hemoglobin concentration was analyzed using Spearman and Pearson correlation for determining the process of changes in the data.Results: The results demonstrated that based on the normal distribution of data at 590 nm wavelength, there is a significantly negative correlation between a function of the signal peak slope and the hemoglobin concentration, with a Pearson coefficient of -0.787 (p
    کلید واژگان
    Hematologic Tests
    Hemoglobinometry
    Photoplethysmography
    Correlation of Data

    شماره نشریه
    6
    تاریخ نشر
    2019-12-01
    1398-09-10
    ناشر
    Shiraz University of Medical Sciences
    سازمان پدید آورنده
    PhD, Department of Biomedical Engineering, Mashhad Branch, Islamic Azad University, Mashhad, Iran
    MSc, Department of Biomedical Engineering, Mashhad Branch, Islamic Azad University, Mashhad, Iran

    شاپا
    2251-7200
    URI
    https://dx.doi.org/10.31661/jbpe.v0i0.400
    https://jbpe.sums.ac.ir/article_44621.html
    https://iranjournals.nlai.ir/handle/123456789/26555

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب