    Determination of TG-43 Dosimetric Parameters for Photon Emitting Brachytherapy Sources

    (ندگان)پدیدآور
    Mozaffari, AGhorbani, M
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.381 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Research
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Objective: Brachytherapy sources are widely used for the treatment of cancer. The report of Task Group No. 43 (TG-43) of American Association of Physicists in Medicine is known as the most common method for the determination of dosimetric parameters for brachytherapy sources. The aim of this study is to obtain TG-43 dosimetric parameters for 60Co, 137Cs, 192Ir and 103Pd brachytherapy sources by Monte Carlo simulation. Methods: In this study, 60Co (model Co0.A86), 137Cs (model 6520-67), 192Ir (model BEBIG) and 103Pd (model OptiSeed) brachytherapy sources were simulated using MCNPX Monte Carlo code. To simulate the sources, the exact geometric characterization of each source was defined in Monte Carlo input programs. Dosimetric parameters including air kerma strength, dose rate constant, radial dose function and anisotropy function were calculated for each source. Each input program was run with sufficient number of particle histories. The maximum type A statistical uncertainty in the simulation of the 60Co, 137Cs, 192Ir and 103Pd sources, were equal to 4%, 4%, 3.19% and 6.50%, respectively. Results: The results for dosimetry parameters of dose rate constant, radial dose function and anisotropy function for the 60Co, 137Cs, 192Ir and 103Pd sources in this study demonstrated good agreement with other studies. Conclusion: Based on the good agreement between the results of this study and other studies, the TG-43 results for Co0.A86 60Co, 67-65200 137Cs, BEBIG 192Ir and OptiSeed 103Pd sources are validated and can be used as input data in treatment planning systems (TPSs) and to validate the TPS calculations.
    کلید واژگان
    Brachytherapy
    TG-43 dosimetric Parameters
    Monte Carlo Method
    60Co
    137Cs
    192Ir
    103Pd

    شماره نشریه
    4
    تاریخ نشر
    2019-08-01
    1398-05-10
    ناشر
    Shiraz University of Medical Sciences
    سازمان پدید آورنده
    Medical Physics Department, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
    Medical Physics Department, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran

    شاپا
    2251-7200
    URI
    https://dx.doi.org/10.31661/jbpe.v0i0.570
    https://jbpe.sums.ac.ir/article_46584.html
    https://iranjournals.nlai.ir/handle/123456789/26519

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب