• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Biomedical Physics and Engineering
    • Volume 9, Issue 2
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Biomedical Physics and Engineering
    • Volume 9, Issue 2
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Evaluation of Electron Specific Absorbed Fractions in Organs of Digimouse Voxel Phantom Using Monte Carlo Simulation Code FLUKA

    (ندگان)پدیدآور
    Sinha, ASingh, NDixit, B MPainuly, N KPatni, H KYadav, A
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    494.9کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: For preclinical evaluations of radiopharmaceuticals, most studies are carried out on mice. Values of electron specific absorbed fractions (SAF) have had vital role in the assessment of absorbed dose. In past studies, electron specific absorbed fractions were given for limited source target pairs using older reports of human organ compositions.Objective: Electron specific absorbed fraction values for monoenergetic electrons of energies 15, 50, 100, 500, 1000 and 4000 keV were evaluated for the Digimouse voxel phantom incorporated in Monte Carlo code FLUKA. The organ sources considered in this study were lungs, skeleton, heart, bladder, testis, stomach, spleen, pancreas, liver, kidney, adrenal, eye and brain. The considered target organs were lungs, skeleton, heart, bladder, testis, stomach, spleen, pancreas, liver, kidney, adrenal and brain. Eye and brain were considered as target organs only for eye and brain as source organs. From the latest report (International Commission on Radiological Protection ICRP) publication number 110, organ compositions and densities were adopted.Results: The electron specific absorbed fraction values for self-irradiation decreases with increasing electron energy. The electron specific absorbed fraction values for cross-irradiation are also found to be dependent on the electron energy and the geometries of source and target. Organ masses and electron specific absorbed fraction values are presented in tabular form. Conclusion: The results of this study will be useful in evaluating the absorbed dose to various organs of mice similar in size to the present study.
    کلید واژگان
    Electron specific Absorbed Fraction
    Digimouse Voxel Phantom
    Monte Carlo Simulation
    FLUKA

    شماره نشریه
    2
    تاریخ نشر
    2019-04-01
    1398-01-12
    ناشر
    Shiraz University of Medical Sciences
    سازمان پدید آورنده
    Faculty of Physical Sciences, Shri Ramswaroop Memorial University, Lucknow, India
    Department of Radiotherapy, King George Medical University, Lucknow, India
    Faculty of Physical Sciences, Shri Ramswaroop Memorial University, Lucknow, India
    Department of Radiotherapy, King George Medical University, Lucknow, India
    Bhabha Atomic Research Center, Mumbai, India
    Department of Radiodiagnosis, Uttar Pradesh Rural Institute of Medical Sciences & Research, Saifai- Etawah, India

    شاپا
    2251-7200
    URI
    https://dx.doi.org/10.31661/jbpe.v9i2Apr.529
    https://jbpe.sums.ac.ir/article_46369.html
    https://iranjournals.nlai.ir/handle/123456789/26399

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب