    Monte Carlo Study of Unflattened Photon Beams Shaped by Multileaf Collimator

    (ندگان)پدیدآور
    kajaria, ASharma, NSharma, ShPradhan, SMandal, AAggarwal, L M
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    792.4کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: This study investigates basic dosimetric properties of unflattened 6 MV photon beam shaped by multileaf collimator and compares them with those of flattened beams.Materials and Methods: Monte Carlo simulation model using BEAM code was developed for a 6MV photon beam based on Varian Clinic 600 unique performance linac operated with and without a flattening filter in beam line. Dosimetric features including lateral profiles, central axis depth dose, photon and electron spectra were calculated for flattened and unflattened cases, separately.Results: An increase in absolute depth dose with a factor of more than 2.4 was observed for unflattened beam which was dependent on depth. PDDs values were found to be lower for unflattened beam for all field sizes. Significant decrease in calculated mlc leakage was observed when the flattening filter was removed from the beam line. The total scatter factor, SCP was found to show less variation with field sizes for unflattened beam indicating a decrease in head scatter. The beam profiles for unflattened case are found to have lower relative dose value in comparison with flattened beam near the field edge, and it falls off faster with distance. Conclusion: Our study showed that increase in the dose rate and lower peripheral dose could be considered as realistic advantages for unflattened 6MV photon beams.
    کلید واژگان
    Monte Carlo Simulation
    Flattening Filter Free Beams
    Multileaf Collimator

    شماره نشریه
    2
    تاریخ نشر
    2019-04-01
    1398-01-12
    ناشر
    Shiraz University of Medical Sciences
    سازمان پدید آورنده
    School of Biomedical Engineering, Indian Institute of Technology (BHU), Varanasi, UP, India
    School of Biomedical Engineering, Indian Institute of Technology (BHU), Varanasi, UP, India
    School of Biomedical Engineering, Indian Institute of Technology (BHU), Varanasi, UP, India
    Department of Radiotherapy and Radiation Medicine, Institute of Medical Science (BHU), Varanasi, UP, India
    Department of Radiotherapy and Radiation Medicine, Institute of Medical Science (BHU), Varanasi, UP, India
    Department of Radiotherapy and Radiation Medicine, Institute of Medical Science (BHU), Varanasi, UP, India

    شاپا
    2251-7200
    URI
    https://dx.doi.org/10.31661/jbpe.v9i2Apr.585
    https://jbpe.sums.ac.ir/article_46367.html
    https://iranjournals.nlai.ir/handle/123456789/26397

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب