• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Biomedical Physics and Engineering
    • Volume 10, Issue 1
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Biomedical Physics and Engineering
    • Volume 10, Issue 1
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Evaluation of MLC Thickness and Composite Effects on Collimation Parameters using EGSnrc and IAEA Phase Space Data

    (ندگان)پدیدآور
    Hadad, KAlipour, H
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    480.0کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Research
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: Recently, multileaf collimators (MLC) have become an important part of any LINAC collimation system because they reduce the treatment planning time and improve the conformity. Important factors that affect MLCs collimation performance are leaves material composition and their thickness.Objective: In this study, we investigate main dosimetric parameters of a typical MLC including dose in the buildup point, physical penumbra as well as average and end leaf leakages. Effects of the leaves geometry and density on these parameters are evaluated. Materials and Methods: In this analytical study, calculations were performed by using phase space data for Varian ix just above MLC and BEAMnrc/DOSXYZnrc for SSD=100cm and in a water phantom. Results: Based on the results, a new MLC with improved dosimetric parameters is proposed. The physical penumbra for proposed MLC is 4.7mm was compared to 5.16 mm for Millennium 120 leaf. Average leakage in our design is reduced to 1.16% compared to 1.73% for Millennium 120 leaf, the end leaf leakage suggested design also reduced to 4.86% compared to 7.26% for Millennium 120 leaf.Conclusion: The results show that the proposed MLC could improve the dosimetric parameters and conformity of treatment planning.
    کلید واژگان
    Phantoms, Imaging
    Radiometry
    Particle Accelerators

    شماره نشریه
    1
    تاریخ نشر
    2020-02-01
    1398-11-12
    ناشر
    Shiraz University of Medical Sciences
    سازمان پدید آورنده
    PhD, Department of Nuclear Engineering, Faculty of Mechanical Engineering, Shiraz University, Shiraz, Iran
    MSc, Department of Nuclear Engineering, Faculty of Mechanical Engineering, Shiraz University, Shiraz, Iran

    شاپا
    2251-7200
    URI
    https://dx.doi.org/10.31661/jbpe.v0i0.658
    https://jbpe.sums.ac.ir/article_44619.html
    https://iranjournals.nlai.ir/handle/123456789/26362

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب