    New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor

    (ندگان)پدیدآور
    Chaibi, HNourine, R
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.079 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Research
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy function which leads to unsatisfactory results.Objective: We propose in this paper a new approach for the generation of a pseudo-CT image from an MR image.Materials and Methods: This approach is based on a dense stereo matching concept, for that, we encode each pixel according to a shape related coordinates method, and we apply a local texture descriptor to put into correspondence pixels between MRI patient and MRI atlas images. The proposed approach was tested on a real MRI data, and in order to show the effectiveness of the proposed local descriptor, it has been compared to three other local descriptors: SIFT, SURF and DAISY. Also it was compared to registration method.Results: The calculation of structural similarity (SSIM) index and DICE coefficients, between the pseudo-CT image and the corresponding real CT image show that the proposed stereo matching approach outperforms a registration one.Conclusion: The use of dense matching with atlas promises good results in the creation of pseudo-CT. The proposed approach can be recommended as an alternative to registration techniques.
    کلید واژگان
    Pseudo-CT
    Attenuation Correction
    Stereo Matching
    Local Texture Descriptor for Matching
    PET/MRI

    شماره نشریه
    1
    تاریخ نشر
    2018-03-01
    1396-12-10
    ناشر
    Shiraz University of Medical Sciences
    سازمان پدید آورنده
    Lab. LITIO, University of Oran 1 Ahmed Ben Bella- Algeria.
    Lab. LITIO, University of Oran 1 Ahmed Ben Bella- Algeria.

    شاپا
    2251-7200
    URI
    https://jbpe.sums.ac.ir/article_43297.html
    https://iranjournals.nlai.ir/handle/123456789/26330

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب