Evaluation of Industrial Dyeing Wastewater Treatment with Coagulants
(ندگان)پدیدآور
پدیدآور نامشخصنوع مدرک
Textزبان مدرک
Englishچکیده
Textile industry is the major source of water consumption and wastewater pollution.There are various treatment techniques to remove textile wastewater pollution. Coagulationflocculation is a widely used process to remove pollution due to suspended particles. In this research, different coagulants like Alum, Lime, FeCl3, FeSO4 and MgCl2 were applied to select the suitable ones with optimum removal efficiency of sulfuric dyes. Settling characteristics of flocs formed in the coagulation process were studied in a laboratory scale settling column unit. Parameters such as color, COD, TSS, turbidity and settled sludge volume have been evaluated. The optimum coagulant dose and pH value were determined by comparing the effectiveness of these coagulants.Results showed other coagulants except lime could eliminate color and COD. In this case, FeSO4 was chosen as an optimum coagulant for color removal because of the lowest required coagulant dose, minimum settled sludge volume and maximum de-colorization.
کلید واژگان
Dye removalCoagulation
Textile wastewater
De-colorization
شماره نشریه
3تاریخ نشر
2007-07-011386-04-10
ناشر
University of Tehran/Springerشاپا
1735-68652008-2304