نمایش مختصر رکورد

dc.contributor.authorMoein, Marziehen_US
dc.contributor.authorPahlavan, Somayehen_US
dc.contributor.authorJahangiri, Mehdien_US
dc.contributor.authorAlidadi Shamsabadi, Akbaren_US
dc.date.accessioned1399-07-09T01:33:30Zfa_IR
dc.date.accessioned2020-09-30T01:33:30Z
dc.date.available1399-07-09T01:33:30Zfa_IR
dc.date.available2020-09-30T01:33:30Z
dc.date.issued2018-01-01en_US
dc.date.issued1396-10-11fa_IR
dc.date.submitted2018-10-29en_US
dc.date.submitted1397-08-07fa_IR
dc.identifier.citationMoein, Marzieh, Pahlavan, Somayeh, Jahangiri, Mehdi, Alidadi Shamsabadi, Akbar. (2018). Finding the Minimum Distance from the National Electricity Grid for the Cost-Effective Use of Diesel Generator-Based Hybrid Renewable Systems in Iran. Journal of Renewable Energy and Environment, 5(1), 8-22. doi: 10.30501/jree.2018.88377en_US
dc.identifier.issn2423-5547
dc.identifier.issn2423-7469
dc.identifier.urihttps://dx.doi.org/10.30501/jree.2018.88377
dc.identifier.urihttp://www.jree.ir/article_88377.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/201503
dc.description.abstractThe electricity economy and its excessive consumption have become one of the main concerns of the Iranian government for many years. This issue, along with recent droughts, shows the need to use renewable energy that is free and clean and does not require water. In addition, due to the high cost of cable-laying and maintenance of power lines, it is not at all an option at all distances over the development of the national electricity grid. Therefore, it is important to find a distance for farther distances so that the use of renewable energy systems can be superior to the national electricity grid. According to related studies conducted so far, nothing has been done in this regard in Iran untill private-sector investors realize that, for what distances from the national grid, the network development is not cost-effective compared to using renewables. Therefore, in the present work, by using NASA's wind and solar data, 102 stations in Iran were investigated using the HOMER software. The studied system is a solar-wind one backed up by batteries and diesel generator for emergency conditions. The results showed that the average total net present cost of the solar-wind hybrid system in Iran was to provide a daily average electricity load of 5.9 kWh of a residential building with a peak load of 806 W equal to $ 12415, which could on average provide 95.3% of the building's needs by renewable energy. The average minimum distance from the national grid is 593 m for the cost-effective use of renewable energy.en_US
dc.format.extent835
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherMaterials and Energy Research Center (MERC) Iranian Association of Chemical Engineers (IAChE)en_US
dc.relation.ispartofJournal of Renewable Energy and Environmenten_US
dc.relation.isversionofhttps://dx.doi.org/10.30501/jree.2018.88377
dc.subjectDiesel generatoren_US
dc.subjectWind Turbineen_US
dc.subjectcost of energyen_US
dc.subjectAdvanced Energy Technologiesen_US
dc.titleFinding the Minimum Distance from the National Electricity Grid for the Cost-Effective Use of Diesel Generator-Based Hybrid Renewable Systems in Iranen_US
dc.typeTexten_US
dc.typeResearch Articleen_US
dc.contributor.departmentDepartment of Architecture, Sepehr institute of Higher Educational, Isfahan, Iranen_US
dc.contributor.departmentDepartment of Architecture, Sepehr institute of Higher Educational, Isfahan, Iranen_US
dc.contributor.departmentDepartment of Mechanical Engineering, Shahrekord Branch, Islamic Azad University, Shahrekord, Iranen_US
dc.contributor.departmentYoung Researchers and Elite Club, Shahrekord Branch, Islamic Azad University, Shahrekord, Iranen_US
dc.citation.volume5
dc.citation.issue1
dc.citation.spage8
dc.citation.epage22