• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Scientia Iranica
    • Volume 21, Issue 4
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Scientia Iranica
    • Volume 21, Issue 4
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    3D-1D Simulation of Flow in Fontan Operation: Effects of Antegrade Flow on Flow Pulsations

    (ندگان)پدیدآور
    Monjezi, MojdehGhoreyshi, MostafaSaidi, M.S.Navabi, Mohammad Ali NavabibFiroozabadi, Bahar D.
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    2.825 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    This study considers blood flow in total cavopulmonary connection (TCPC) morphology, created in Fontan surgical procedure in patients with a single ventricle heart disease. Ordinary process of TCPC operation reduces pulmonary blood flow pulsatility; since the right ventricle being bypassed. This reduction may limit the long term outcome of Fontan circulation. There is an idea of increasing pulmonary flow pulsations by keeping main pulmonary artery (MPA) partially open while it was closed in ordinary TCPC operation. The purpose of the present study is to verify the effects of antegrade flow (AF) coming through stenosed MPA on pulmonary flow pulsations. The 3-D geometry is reconstructed from CT angiography scan of a patient who has undergone an ordinary TCPC procedure. The stenosed MPA or pulmonary stenosis (PS) is virtually added to the original geometry. We applied a 3D-1D coupled method to simulate blood flow in this situation more precisely. The results show that adding AF increases pulsatility index (PI) in both left and right pulmonary artery (LPA and RPA respectively). Moreover, adding AF leads to an increase in energy loss. It also increases the pulmonary-to-systemic flow ratio leading to increase in total cardiac flow rate and hence heart power.
    کلید واژگان
    Fontan operation
    Total cavopulmonary connection (TCPC)
    Computational fluid dynamics (CFD)
    Flow pulsations
    Antegrade flow (AF)

    شماره نشریه
    4
    تاریخ نشر
    2014-08-01
    1393-05-10
    ناشر
    Sharif University of Technology
    سازمان پدید آورنده
    Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
    Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
    Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
    Department of Pediatric Cardiac Surgery, Imam Hospital, Children's Medical Center, Tehran ‎University of Medical Sciences, Tehran, Iran
    Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran

    شاپا
    1026-3098
    2345-3605
    URI
    http://scientiairanica.sharif.edu/article_3560.html
    https://iranjournals.nlai.ir/handle/123456789/119031

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب