A Meshless Method to Simulate the Interactions Between A Large Soft Tissue and A Surgical Grasper
(ندگان)پدیدآور
Saghaei Nooshabadi, ZeinabAbdi, ElaheFarahmand, FarzamNarimani, RoyaChizari, Mahmoudنوع مدرک
Textزبان مدرک
Englishچکیده
Realistic simulation of tool-tissue interactions can help to develop more effective surgical training systems and simulators. This study used a finite element and meshless modeling approaches to simulate the grasping procedure of a large intra-abdominal organ, i.e., kidney, during laparoscopic surgery. Results indicated that the accuracy of meshless method was comparable with that of the finite element, with the root mean square errors in the range of 0.8 to 2.3 mm in different directions. For the model presented in this study, the computational cost of the meshless method, was much less than that of the finite element model.
کلید واژگان
Intra-abdominalLarge Deformation
Finite Element
meshless method
شماره نشریه
1تاریخ نشر
2016-02-011394-11-12
ناشر
Sharif University of Technologyسازمان پدید آورنده
Mechanical Engineering Department Sharif University of Technology P.O.Box 11155-9567 Azadi Ave, Tehran, IranInstitute of Microengineering EPFL CH-1015 Lausanne, Switzerland
Mechanical Engineering Department Sharif University of Technology RCBTR, Tehran University of Medical Sciences P.O.Box 11155-9567 Azadi Ave, Tehran, Iran
Mechanical Engineering Department Sharif University of Technology P.O.Box 11155-9567 Azadi Ave, Tehran, Iran
Mechanical Engineering Department Sharif University of Technology P.O.Box 11155-9567 Azadi Ave, Tehran, Iran
شاپا