    Molecularly Imprinted Polymer (MIP) Electrochemical Sensor based on Graphene Modified Platinum Electrode for Sertraline Determination

    (ندگان)پدیدآور
    Milani-Hosseini, Mohammad-RezaKaramdoust, SanazBahman, MinaMotaharian, AliMohammadsadegh, Saeideh
    Thumbnail
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    In this report, a new electrochemical sensor was developed for sertraline (STR) analysis. The sensor was prepared based on modified Pt electrode with graphene nanoparticles and molecular imprinting polymer (MIP) by coating a very thin layer of polymer onto a support. Through this approach, all of the binding sites of the polymer immobilized on the electrode surface are available for target molecules. The STR binding experiments indicated that the sensor modified by MIP have much higher adsorption ability than non−imprinted polymer (NIP) based sensor. Also, using of graphene in preparation of Pt electrode leads to a significant improvement in response of electrode because of their high electrical conductivity and large surface areas as the platform of the polymer that makes the graphene-MIP an excellent electrical transducer for direct electrical sensing. The cyclic voltammetry (CV) and differential pulse voltammetry (DPV) tests were used to evaluate the performance of the electrochemical sensor. Some parameters affecting the sensor performance such as MIP suspension, extraction pH and preconcentration time were optimized and under optimal conditions, the modified sensor with MIP-graphene showed linear responses with STR concentration in the range of 1.0×10-8 to 1.0×10-6 mol L-1 (R2 = 0.985) with a detection limit of 7.0×10-9 mol L-1. This developed sensor with the MIP was consequently capable of selective sensing of STR in human serum sample with recovery values in the range of 98.2-103.5%.
    کلید واژگان
    sensor
    Molecularly imprinted polymer
    Graphene
    Sertraline
    Electroanalysis

    شماره نشریه
    1
    تاریخ نشر
    2020-01-01
    1398-10-11
    ناشر
    University of Tehran
    سازمان پدید آورنده
    Research Laboratory of Real Samples Analysis, Department of Analytical Chemistry, Faculty of Chemistry, Iran University of Science and Technology, Tehran, Iran
    Research Laboratory of Real Samples Analysis, Department of Analytical Chemistry, Faculty of Chemistry, Iran University of Science and Technology, Tehran, Iran
    Research Laboratory of Real Samples Analysis, Department of Analytical Chemistry, Faculty of Chemistry, Iran University of Science and Technology, Tehran, Iran
    Research Laboratory of Real Samples Analysis, Department of Analytical Chemistry, Faculty of Chemistry, Iran University of Science and Technology, Tehran, Iran
    Research Laboratory of Real Samples Analysis, Department of Analytical Chemistry, Faculty of Chemistry, Iran University of Science and Technology, Tehran, Iran

    شاپا
    2008-4226
    URI
    https://www.abechem.com/article_717565.html
    https://iranjournals.nlai.ir/handle/123456789/1152635

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب