    Electrochemical Sensor for Selective Determination of Ketorolac Tromethamine based on Molecularly Imprinting Polypyrrole Modified with Functionalized Multi-wall Carbon Nanotubes in Pharmaceutical and Biological Samples

    (ندگان)پدیدآور
    Nezhadali, AzizollahBiabani, Mohadese
    Thumbnail
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    In this project, using a molecularly imprinting polypyrrole (MIP) modified with functionalized multi-wall carbon nanotubes (MWCNTs), a selective and sensitive electrochemical sensor constructed to measure ketorolac tromethamine (KT). Cyclic Voltammetry (CV), differential pulse Voltammetry (DPV) and chronoamperometry methods, respectively was performed in preparation of MIP, quantitative measurements and deposition of MWCNTs on the bare paper graphite electrode (PGE) surface. The nine factors were chosen for the investigation, which are: the concentration of MWCNTs, deposition time of MWCNTs onto the bare PGE surface, concentration of pyrrole, concentration of KT, number of cycles in electropolymerization, the pH of the polymerization solution, scan rate of CV process, electrode loading time, and stirring rate of loading solution. The multivariate methods,including Plackett-Burman design (PBD), and central composition design (CCD) were usedfor screening and optimizing of factors that could influence on the analytical response,respectively. Under the optimized conditions, the proposed MIP sensor showed a linear rangefrom 4.0×10-6 to 6.0×10-3 M KT concentration with a correlation coefficient (R2) of 0.9903.The limit of detection was obtained 0.12 μM (3Sb/m, n=6) with a highly reproducible response(RSD 4.45%, n=4). The electrochemical sensor showed good results for the determination ofKT in pharmaceutical and biological samples.
    کلید واژگان
    Polypyrrole
    Ketorolac tromethamine
    Molecularly imprinting polypyrrole
    Multi-Wall Carbon Nanotubes
    Sensor

    شماره نشریه
    1
    تاریخ نشر
    2020-01-01
    1398-10-11
    ناشر
    University of Tehran
    سازمان پدید آورنده
    Department of Chemistry, Payame Noor University, PO. Box 19395–4697, Tehran, Iran
    Department of Chemistry, Payame Noor University, PO. Box 19395–4697, Tehran, Iran

    شاپا
    2008-4226
    URI
    https://www.abechem.com/article_717560.html
    https://iranjournals.nlai.ir/handle/123456789/1152630

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب